Page 8
Getting Started
PUMP
UNIONS
PUMP
UNIONS
HEATER
UNIONS
DRAIN
PLUG
DRAIN
PLUG
PRIMING THE PUMP(S)
Upon filling or refilling the spa, if a pump is operating and water is not flowing from any
of its jets, the pump may not be properly primed. To correct, refer to the illustration below
and perform the following procedures:
• Turn off power to the spa at the breaker and remove the equipment
compartment door.
• Loosen
the union on the top of the pump(s) to allow the air to escape. When
water is present, hand-tighten the union.
• Turn power back on, activate the pump and check to make sure union is
tight enough to keep it from leaking. Re-install equipment door.
NOTE: Equipment compartment illustrated below will vary depending on
spa model.
IMPORTANT
THE DRAIN CAP AND UNION FITTINGS IN THE EQUIPMENT COMPARTMENT
MAY LOOSEN DURING TRANSPORTATION. TO AVOID LEAKS, PLEASE
CHECK TO MAKE SURE THESE ARE HAND-TIGHT
PRIOR TO FILLING YOUR SPA.