5
REINKE PIVOTS
WIRING INSTRUCTIONS FOR BASIC OPERATION
Typically all functions switches are off unless advanced features are needed. See function
switch setting on page 3 for details.
To supply the 120vac needed for the Hot Shot Transmitter to operate, run a wire from
the pivot panel
’
s J13 terminal to the 120vac Hot terminal on the transmitter. Run another wire
from the pivot panel
’
s neutral terminal J9 to the 120vac neutral terminal on the transmitter.
Make sure the pivot
’
s well kill terminals DO NOT have any voltage from previously
wired configurations. Run a wire from terminal J12 to the Hot Shot Transmitter
’
s COM input
terminal. Run a wire from terminal J11 to the Hot Shot Transmitter
’
s ON
-
OFF INPUT termi-
nal. Connect a wire from the Lighting Ground terminal of the Hot Shot Transmitter to an NEC
approved earth ground rod.
See diagram below.