Hot Shot 810-T Скачать руководство пользователя страница 3

3

 

CODE SWITCH SETTINGS

 

All transmitters and receivers will be shipped from the factory with preprogrammed 4 digit system codes. This 

ensures that your neighbor will not duplicate the same system code as your units. Your transmitter and receiver 

system codes should already match, so you do not need to program any codes. If a new secure system code is 

needed for your installation please call 785

-

623

-

1500 to be issued a secure system code for your area that the 

system will be operating in.

 

 

If you ever need to replace a unit due to servicing, the field code can be programmed to match the existing or 
new add on units.  FOLLOW THE EXAMPLE BELOW

 

FOR CODE QUESTIONS? CALL 785

-

623

-

1500

 

8

 

9

 

7

 

EXAMPLE: CODE 

6789

 

KEY

 

7

 

 

8

 

 

9

 

 

0

 

 

5

 

 

6

 

3

 

 

4

 

 

6

 

O

FF

   

 O

N

 

Use the # KEY to the left 

to make each digit of the 

code.  It takes three of the 

switches to make one num-

ber of the code.

 

Use switches 1,2,3 for the 

first # in the code.  Switches 

4,5,6 for the second #.  

Switches 7,8,9 for the third 

#.  Switches 10,11,12 for the 

fourth #.

 

Code Switches

 

INDICATOR LEDS

 

 
 
 
 

 
 

POWER

 

 

Indicates that the Transmitter has power and is 

ready to operate.

   

 

 

 

TRANSMITTING

 

Indicates when the Transmitter is transmitting.

   

 

 

 

 

 

SENSOR LEDS

 

When these LED

s are on it indicates that the terminal below it is connected to the COMMON terminal. 

 

SENSOR LEDS

 

TRANSMITTER FUNCTION SWITCH SETTINGS

 

SWITCH#

 

4

 

ON

 

MAKES TRANSMITTER A UNIT #2 TRANSMITTER

 

 

4&5 both

 

ON

 

MAKES TRANSMITTER A UNIT #3 TRANSMITTER

 

 

5

 

ON

 

MAKES TRANSMITTER A UNIT #4 TRANSMITTER

 

 

5&6 both

 

ON

 

MAKES TRANSMITTER A UNIT #5 TRANSMITTER

 

 

6

 

ON

 

MAKES TRANSMITTER A UNIT #6 TRANSMITTER

 

 

 

 

(see more about this feature on page 12)

 

 

8

 

ON

 

 ACTIVATES THE TEST BEACON  (Used for testing and range finding only.  When activated the transmitter will 

send a code every 10sec cycling the receivers relay.   

To activate this feature put a jumper wire from the ON

-

OFF INPUT to 

COMMON on the relay input you want to test.  DO NOT have the receiver wired to the pump during this test.  This func-
tion must be turned off for normal operation. (More details on page 4)

 

 

OFF

 

 NORMAL OPERATION MODE 

 

 

 

 

 

 

 

9

 

ON

 

REFRESH (This function will retransmit the state of the Sensor Inputs once every 45 minutes.)

 

 

OFF

 

NO REFRESH (Transmits the code only when there is a change of state on the Sensor Inputs.)

 

 

To watch a 

How To

” 

video on this feature click on the link below:

 

CODE SWITCH SETTINGS

 

Содержание 810-T

Страница 1: ...T L ENGINE PIVOT ISUZU PANEL 10 ZIMMATIC PIVOT 10 WIRE SYSTEM 11 ZIMMATIC PIVOT 11 WIRE SYSTEM 12 UNIT SETTINGS 13 GROUNDING Version 160825 Hot Shot Systems Inc will no longer sell or warranty its products for the use in controlling or monitoring pollu tants However the use of these controllers in non pollutant applications such as water tanks water pumps pivots irrigation systems and any other mo...

Страница 2: ...cted NEMA 4X cabinet with mounting ears on top and bottom The trans mitter receiver control box can be mounted on the side of a control panel pole or any other surface as long as the antenna does not have metal running within 12 of the antenna whip If longer range is needed an external long range antenna can be used Do not mount the HOT SHOT receiver to the well engine or cover because the strong ...

Страница 3: ...itter has power and is ready to operate TRANSMITTINGIndicates when the Transmitter is transmitting SENSOR LEDS When these LED s are on it indicates that the terminal below it is connected to the COMMON terminal SENSOR LEDS TRANSMITTER FUNCTION SWITCH SETTINGS SWITCH 4 ON MAKES TRANSMITTER A UNIT 2 TRANSMITTER 4 5 both ON MAKES TRANSMITTER A UNIT 3 TRANSMITTER 5 ON MAKES TRANSMITTER A UNIT 4 TRANSM...

Страница 4: ...ycling the receiver s relay DO NOT have the receiver relay wired up to the pump during this procedure because it will continually open the relay for 10 seconds and then close the relay for 10 seconds causing damage to the pump Function switch 8 must be turned OFF the jumper wire removed and then turn off the power on the transmitter power switch to take it out of Beacon Mode Trans Terminal Strip S...

Страница 5: ...l on the transmitter Run another wire from the pivot panel s neutral terminal J9 to the 120vac neutral terminal on the transmitter Make sure the pivot s well kill terminals DO NOT have any voltage from previously wired configurations Run a wire from terminal J12 to the Hot Shot Transmitter s COM input terminal Run a wire from terminal J11 to the Hot Shot Transmitter s ON OFF INPUT termi nal Connec...

Страница 6: ...t ter Run another wire from the pivot panels neutral buss bar to the second 120vac Neutral input on the transmitter With these models we recommend that you use terminal 3 and 4 on the 3 Sec Delay PCB to control the Sensor on the Hot Shot Transmitter Remove the wires that currently go in to them and cap them off Run a wire from terminal 3 on the 3 Sec Delay PCB to the COM input on the transmitter R...

Страница 7: ...ac Hot to the 120vac Hot terminal on the transmitter Run another wire from the pivot panels terminal 9 or 10 120vac Neutral to the 120vac Neutral terminal on the transmitter To connect the pivot panels well control relay to the Hot Shot Transmitter run a wire from terminal 15 PUMP CONTROL NO to the transmitters ON OFF input terminal Now run a wire from terminal 16 PUMP CONTROL COM to the transmitt...

Страница 8: ...former to terminal 9 and 11 in the T L Allen Bradley Panel Then take the 2 wires from the 120VAC output side and run them to the trans mitters two 120vac inputs INSTALL a 24vac relay Interface Relay to control the Sensor input on the transmitter Control the Interface Relay by running a wire from the Allen Bradley panel s terminal 1 and 2 to each side of the Interface Relays coil terminals Run a wi...

Страница 9: ...ay to control the SENSOR inputs on the transmitter To control the 12vdc Interface Relay run a wire from the engines Murphy switch terminal C on a 117 or from the terminal NC on a 518 to one side of the relays coil terminals Run another wire from the ground on the Murphy or from the NEG of the Hot Shot Transmitter to the other coil terminal on the 12vdc Interface Relay Now run a wire from the 12vdc...

Страница 10: ... another wire from the 120v X2 terminal to the 120vac Neutral terminal on the transmitter INSTALL a 24vac relay Interface Relay to control the Sensor input on the transmitter Control the Inter face Relay by running a wire from one side of the relay coil to terminal 64 and connect the other side of the relay coil to terminal 4 Wire the N O side of the Interface Relay to the ON OFF INPUT terminal on...

Страница 11: ...another wire from the 120v X2 terminal to the 120vac Neutral terminal on the transmitter INSTALL a 24vac relay Interface Relay to control the Sensor input on the transmitter Control the Inter face Relay by running a wire from one side of the relay coil to terminal 64 and connect the other side of the relay coil to terminal 65 Wire the N O side of the Interface Relay to the ON OFF INPUT terminal on...

Страница 12: ...r unlicensed business or personal use Any changes or modifications may void the user s authority granted by the FCC to operate this radio and should not be made Use of this radio outside the country where it was intended to be distributed is subject to gov ernment regulations and may be prohibited UNIT FUNCTION SWITCHES 4 5 6 Using unit s on the transmitters and receivers can create a more precisi...

Страница 13: ...ection devices incorporated on the cir cuit board that require proper grounding to operate Any equipment or device panels operating with or near the Hot Shot should also be con nected to the grounding system A good ground will enhance the trans mit and receive range of the Hot Shot System GROUNDING PER NATIONAL ELECTRICAL CODE DEVICE PANEL To watch a How To video on this feature click on the link ...

Страница 14: ... s Guidelines Unintended use are at the End User s own risk and Hot Shot Systems does not warrant or make any representations whatsoever regarding the use of Products for any unintended use Hot Shot Systems Products are convenience items and are not intended to be a substitute for normal maintenance monitoring control and proper upkeep of equipment or property that Products are monitoring or contr...

Отзывы: