Service and Maintenance / Color Coding of Thermocouples
10.2 MS-Heating Element
There are two types of
M
olding
S
olution heaters.
Front Heaters
F
HA#-0##-###-## and Head Heaters
H
HA#-0##-###-##.
The thermocouple is pressed in firmly and cannot be replaced.
All heaters are available either with a thermocouple type J (#HA
J
-0##-###-##) or a thermocouple type K (#HA
K
-0##-###-##).
10.2.1 Color Coding of Thermocouples
NOTICE
Take notice of the production and color identification of thermocouple cables.
Synventive uses J and K type thermocouples. Their color coding is given in the following table.
Table 1: International color coding for temperature sensors
Type
International standard IEC 584-3
J
Black
+ Black
- White
K
Green
+ Green
- White
Coating
Litz wire “+”
Litz
wire
“-”
Doc008133.png