20
c) Drain Frequency Control (S1 dip switch 4)
This unit is factory set for optimum performance with the 1-in-1 drain cycle (S1 dip
switch 4 in the "OFF" position). This setting allows for removal of sediment from the
evaporator without interrupting the icemaking process. An optional 1-in-12 drain cycle is
available.
S1 Dip Switch Setting
Drain Timer Interval Drain Valve Open
No. 4
OFF (1-in-1)
1 Hour
2 Seconds
ON (1-in-12)
11 Hours 45 Minutes
10 Minutes
d) Continuous Dispensing Timer (S1 dip switch 5 & 6)
DCM models only. The dispense mode switch on DCMs must be in the "CONTINUOUS"
position for this setting to apply. The factory setting allows ice to be dispensed
continuously as long as the dispense solenoid is activated.
S1 Dip Switch Setting
Dispense Time
No. 5
No. 6
OFF
OFF
No Limit
ON
OFF
20 Seconds
OFF
ON
60 Seconds
ON
ON
No Limit
e) Bin Control Selector (S1 dip switch 7)
This unit is factory set for infrared sensor bin control operation. No adjustment is
required. When used on a standard ice storage bin, the mechanical bin control may be
used instead of the infrared sensor by moving S1 dip switch 7 to the off position. In the
factory default position (S1 dip switch 7 in the on position), the gear motor delay after the
upper float switch closes is 30 seconds. When the mechanical bin control is used (S1
dip switch 7 in the off position), the gear motor delay after the upper float switch closes is
5 seconds.
WARNING! Do not place S1 dip switch 7 in the off position on dispenser
unit applications.
S1 Dip Switch
Setting
Bin Control Application
Gear Motor Delay
No. 7
OFF
Mechanical Bin Control (Standard Ice Storage Bins Only)
5 seconds
ON
Infrared Sensor with
Mechanical Bin Control Backup
30 seconds