34
Infrared Sensor
Infrared Sensor
Housing
Lens
Infrared Sensor LED
Infrared Sensor LED
Fig. 3
Thumbscrew
Fig. 4
Chute Assembly
Actuator Paddle
Spout
Strap
Proximity Switch
Strap
2. Mechanical Backup Bin Control Check
When the actuator paddle is not engaged MBC is closed and the icemaker produces ice.
a) Mechanical Backup Bin Control
: S1 dip switch 7 placed in the "ON" position, MBC
is used as a backup bin control safety. When ice fills the chute and engages the actuator
paddle, MBC opens and CB shuts down the icemaker within 10 seconds and sounds a
9-beep alarm.
b) Stand-Alone Mechanical Bin Control
: S1 dip switch 7 placed in the "OFF" position,
MBC is used as a stand-alone bin control. The stand-alone application should only be
used in Hoshizaki standard ice storage bin applications.
WARNING! Do not place S1
dip switch 7 in the "OFF" position on dispenser unit applications.
When ice fills the
chute and engages the actuator paddle, MBC opens and CB shuts down the icemaker
within 10 seconds.
1) Remove the front panel.
2) Move the power switch to the "OFF" position, then unplug the unit from the electrical
outlet.
3) Remove the strap connecting the spout to the chute assembly. See Fig. 4. Pull up the
chute assembly slightly so that you can access the actuator paddle located in the top of
the chute.
4) Plug the unit into the electrical outlet.
5) Move the power switch to the "ON" position to start the automatic icemaking process.
9) Remove the object covering IS. If you removed IS housing from the base, replace it in
its correct position, and secure it with the thumbscrew.
10) Move the power switch to the "OFF" position. Unplug the icemaker from the electrical
outlet, then proceed to "IV.D.2. Mechanical Backup Bin Control Check."