Water

Test Paper

pH

Available Chlorine

Sanitizing

pH test paper UNIV Approx. 3

Chlorine test paper

20 mg/kg (ppm)

or more

Cleaning

pH test paper UNIV Approx. 11

Neutralizer pH test paper UNIV 5.8 or more

* It is not necessary to check the available chlorine concentration of 

cleaning water.

Note: See the instruction manual of each test paper for details of its 

proper handling.

 

If any of the checked values exceeds the specified range, 

contact an authorized Hoshizaki service company.

 

If water is not dispensed from its proper outlet, contact an 

authorized Hoshizaki service company.

[b] SALT LEVEL (DAILY)

Check the salt level according to “3. [a] SALT LEVEL”.

[c] NEUTRALIZING AGENT LEVEL (DAILY)

The neutralizer prevents vaporization of chlorine generated from 

water overflowing the sanitizing water tank. Water overflowing the 

cleaning water tank is not neutralized but flows through the neutralizer 

without changing its pH.

Check the neutralizing agent level according to “3. [b] NEUTRALIZING 

AGENT LEVEL”.

[d] WATER LEAKS (DAILY)

Check the unit and surrounding floor for water leaks. If any is found, 

contact an authorized Hoshizaki service company.

[e] REPLACE CELL LAMP (DAILY)

Check that the replace cell lamp on the operation panel is not flashing. 

The service life of the electrode in the electrolytic cell depends on 

water quality. To maintain effective performance of electrolyzed 

water, the electrolytic cell needs to be replaced every 3000 hours of 

operation.

If  the  replace  cell  lamp  is  flashing,  contact  an  authorized  Hoshizaki 

service company.

[f] CELL RUN TIME, CURRENT, VOLTAGE (AS REQUIRED)

To check the cell run time, current, and voltage:

1) Open the door.

2) Turn on the power switch (

earth leakage circuit breaker).

3) Press the display select button on the control panels (A) and (B) 

[ROX-30SA-EW: control panel (A) only].

4) Press the display select button until the desired item appears in the 

display.

Note: It is factory adjusted to display the cell run time first.

5) Close the door.

[g] WATER HARDNESS (WEEKLY)

IMPORTANT

Continuous use with hard water may cause clogged pipes, 

reduction in performance, or failure of the electrolytic cell. If 

sampled water is hard, contact an authorized Hoshizaki service 

company.

1) Open the water sampling tap. Let water 

run for more than 5 seconds. Sample 

water in the measuring cup.

2) Pour one or two drops of the water 

hardness indicator into the measuring 

cup, and stir a little. Check the water 

hardness (red = hard water, blue = soft 

water).

Water 

sampling tap

Open

OFF

Test button

1) Press the test button of the power switch 

(earth leakage circuit breaker).

2) Check that the switch turns off. If not, 

immediately contact an authorized 

Hoshizaki service company.

[i] ATTACHMENT PLUG (ANNUALLY/BIANNUALLY)

WARNING

Check periodically that the attachment plug blades and their 

vicinity are free of dust and that the attachment plug is securely 

plugged into the receptacle. Dusty blades or loose connection 

may cause electric shock or fire.

Check for the following problems:

Problem

Remedy

The attachment plug or power cord 

is too hot, damaged, weighed down, 

or caught in.

Immediately ask an authorized 

Hoshizaki service company for 

repair.

The attachment plug blades, their 

vicinity, and receptacle are dusty.

Clean.

The attachment plug is plugged 

into a single receptacle with other 

equipment.

Plug into a separate receptacle.

The unit shares a single power 

supply with other equipment.

Use a separate power supply.

[j] CONSUMABLE/PERIODIC REPLACEMENT PARTS

Consumable parts:

 

pH test paper UNIV  

Chlorine test paper

 

Water hardness indicator 

Neutralizing agent

Periodic replacement parts:

 

Electrolytic cell (3000 hours)

9. PREPARING ELECTROLYZER FOR LONG STORAGE

WARNING

When shutting down the electrolyzer for more than a week, turn 

off the power switch (earth leakage circuit breaker), and unplug 

the unit to prevent electric leak, heat generation, or ignition.

CAUTION

When shutting down the electrolyzer for more than two days, 

drain out the unit to prevent foul water from causing bacterial 

growth and health problems.

Note: For details, follow the instructions of the water hardness 

indicator.

[h] EARTH LEAKAGE CIRCUIT BREAKER (MONTHLY)

WARNING

Check the earth leakage circuit breaker for proper operation 

once a month. If it is left inoperable, it could increase the risk of 

electric shock in case of electric leak.

Содержание ROX-30SA-EW

Страница 1: ...ROX 30SA EW ROX 60SA EW L1X007115 032017 WATER ELECTROLYZER FOR END USER INSTRUCTION MANUAL 3 16 Minamiyakata Sakae Toyoake Aichi 470 1194 Japan ...

Страница 2: ...rdance with current regulations according to the manufacturer s instructions This electrolyzer is not intended for outdoor use including under canopy Exposure to rain may cause electric leak or shock Direct sunlight can damage the plastic tank exterior resulting in cracks and water leaks Ensure adequate ventilation Hydrogen gas or chlorine gas may cause health problems Do not mix electrolyzed wate...

Страница 3: ...Acid HOCl Sodium Hydroxide NaOH Cathode RED Anode OX Positive ions drawn to cathode Cl Negative ions drawn to anode Salt Water NaCl Diaphragm Electrolytic Cell Flow of electrons Cl H2O H2O Na Na Na Na Na OH OH 2e 2e H2 HOCl Reactions at Anode Chloride ions Cl and hydroxide ions emit electrons e to the anode which become hypochlorous acid HOCl Reactions at Cathode Sodium ions Na receive electrons e...

Страница 4: ...stored in the tank 2 Tank level lamp green Indicates the water level for each tank in three steps Electrolyzed water is not available if this lamp is off 3 Flush reverse dispense lamp blue The sanitizing and cleaning water outlets are switched while this lamp is on Check with the electrolyzed water lamp 4 Replace cell lamp red Flashes when the electrolytic cell needs to be replaced 5 Error lamp re...

Страница 5: ...um chloride KCl with more than 99 purity Any other kind of salt may cause failure clogged pipes or health problems 2 To prevent corrosion do not spill salt 3 Tightly close the salt chute door to avoid dust and dirt that may cause failure Blue line Salt chute Salt net Check the add neutralizer lamp on the operation panel If it is flashing follow steps 1 to 4 below 1 Uncap the neutralizer Add in neu...

Страница 6: ...mp cloth IMPORTANT 1 Do not damage the stainless steel surfaces Use of a steal brush or steel wool may break oxide film to develop corrosion inside 2 Use a calcium chloride based liquid cleanser to remove corrosion dirt and chlorides 3 Clean the stainless steel surfaces along with their grains if any b CLEANING WATER CIRCUIT MONTHLY The cleaning water circuit has calcium and magnesium deposits Con...

Страница 7: ...ipes reduction in performance or failure of the electrolytic cell If sampled water is hard contact an authorized Hoshizaki service company 1 Open the water sampling tap Let water run for more than 5 seconds Sample water in the measuring cup 2 Pour one or two drops of the water hardness indicator into the measuring cup and stir a little Check the water hardness red hard water blue soft water Water ...

Страница 8: ...OFF switch again to resume operation When one of the following error codes appears immediately contact an authorized Hoshizaki service company Lamp Code Problem Possible Cause Remedy Flash E14 Water valve defective Repair or replacement is required Contact an authorized Hoshizaki service company E31 Water valve salt water tank defective E53 Reversing relay defective E61 Flow switching valve defect...

Страница 9: ...ly 5 30 C Water Supply Comply with local water requirements Pressure 0 10 0 75MPa with pressure reducing valve Model ROX 60SA EW Electrolysis System Membrane technology Electrolyte Salt containing at least 99 sodium chloride Power Supply 1 phase 220 240V 50 60Hz Electric Consumption 460W Pump operation 760 890W Performance Standard Sanitizing water pH3 or less available chlorine 20 60mg kg Cleanin...

Страница 10: ...ntration Salt level Neutralizing agent level Water hardness Water leaks around unit Water leaks from water circuit Cell run time Checked by Sanitizing water only Date Time pH Sanitizing water Cleaning water Neutralizer Available chlorine concentration Salt level Neutralizing agent level Water hardness Water leaks around unit Water leaks from water circuit Cell run time Checked by Sanitizing water ...

Отзывы: