3
[13]
[14]
[15]
(Bottom)
Front
[13] Drain outlet (G3/4 female)
[14] Tank drain outlet (G1/2 female)
[15] Water inlet (Rc1/2 female)
[b] INTERIOR
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[1] Power switch (earth leakage circuit breaker)
Turns on and off the power supply.
[2] Control panel (B)
ROX-60SA-EW only. Provided with buttons and display for setting cell
functions. See “[d] CONTROL PANEL (A) (B)”.
[3] Water softener
Softens tap water.
[4] Salt water tank
Dilutes salt to make salt water.
[5] Neutralizer
Neutralizes sanitizing water pH.
[6] Neutralizer inlet
Open to add in neutralizing agent.
[7] Door
Open/close to evacuate the salt water pump and add in neutralizing
agent.
[8] Water sampling tap
Sample water to check water hardness.
[9] Control panel (A)
Provided with buttons and display for setting cell functions. See “[d]
CONTROL PANEL (A) (B)”.
[10] Water softener timer
Sets the present time and regeneration time. See “[e] WATER
SOFTENER TIMER”.
[c] OPERATION PANEL
[1] Electrolyzed water lamp
(Blue = cleaning water, red = sanitizing water)
Indicates the type of water stored in the tank.
[2] Tank level lamp (green)
Indicates the water level for each tank in three steps. Electrolyzed
water is not available if this lamp is off.
[3] Flush (reverse dispense) lamp (blue)
The sanitizing and cleaning water outlets are switched while this lamp
is on. Check with the electrolyzed water lamp.
[4] Replace cell lamp (red)
Flashes when the electrolytic cell needs to be replaced.
[5] Error lamp (red)
Comes on or flashes in case of trouble.
[6] ON/OFF switch
Starts and stops electrolyzing water.
[7] Operation lamp (green)
Stays on while the unit is in operation.
(ROX-60SA-EW: Flashes when one unit is off.)
[8] Add salt lamp (red)
Comes on when the salt water tank is running out of salt.
[9] Reset switch
Resets the add neutralizer lamp.
[10] Add neutralizer lamp (red)
Flashes when the neutralizer is getting empty.
Note: Whether the operation lamp is on or off, electrolyzed water is
available while the power switch is on, until the tank level lamp
goes off.
[d] CONTROL PANEL (A) (B) [ROX-30SA-EW: Control panel (A) only]
[1] [10] [9] [8] [7]
[2]
[3]
[4]
[5]
[6]
[1]
[2]
[3]
[4]
[5]
[7]
[6]
[1] Display
Indicates the cell run time, current, voltage, and error code in case
of trouble. Shows “STOP” when electrolysis stops for water softener
regeneration.