IMPORTANT SAFETY INFORMATION

Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage 

to the unit.

WARNING

Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION

Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE

Indicates a hazardous situation which, if not avoided, could result in damage to the unit.

HYGIENE

Indicates important precautions for hygiene and food safety.

IMPORTANT

Indicates important information about the use and care of the unit.

IMPORTANT

This booklet is an integral and essential part of the product and should be kept and preserved by the user. 
Please read carefully the guidelines and warnings contained herein as they are intended to provide the user with essential 

information for the continued safe use and maintenance of the product. In addition, it provides GUIDANCE ONLY to the user 

on the correct services and site location of the electrolyzer. 
Please preserve this booklet for any further consultation that may be necessary.

WARNING

This is a water electrolyzer, and should be destined only to be used for the purpose for which it has been expressly designed.

Any other use should be considered improper and therefore dangerous. The manufacturer will not be held liable or responsible 

for any damage caused by improper, incorrect and unreasonable use.

The installation, and relocation if necessary, must be carried out by qualified personnel

, in accordance with current 

regulations, according to the manufacturer’s instructions.
This electrolyzer is not intended for outdoor use (including under canopy). Exposure to rain may cause electric leak or shock. 

Direct sunlight can damage the plastic tank exterior, resulting in cracks and water leaks.
Ensure adequate ventilation. Hydrogen gas or chlorine gas may cause health problems.
Do not mix electrolyzed water with other chemicals. Mixture with acidic or chlorine-based chemicals can cause chlorine gas, 

resulting in health problems.
Do not use a large volume of sanitizing water only. Generation of a large amount of chlorine gas may cause health problems 

or corrosion of surrounding equipment.
The use of any electrical appliance involves the observance of some fundamental rules. In particular:

* Instances of high humidity and moisture increase the risk of electrical short circuits and potential electrical shocks. If in 

doubt, disconnect the electrolyzer.

* Do not damage the power cord or pull it in order to disconnect the electrolyzer from the electrical supply network.

* Do not touch the electrical parts or operate the switches with damp hands.

* This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, 

or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance 

by a person responsible for their safety.

* Children should be supervised to ensure that they do not play with the appliance.

* Do not attempt to modify the electrolyzer. Only qualified personnel may disassemble or repair the appliance.

CAUTION

Do not use a flame near a container or tank holding electrolyzed water. Hydrogen gas from cleaning water may cause ignition.

Содержание ROX-30SA-EW

Страница 1: ...ROX 30SA EW ROX 60SA EW L1X007115 032017 WATER ELECTROLYZER FOR END USER INSTRUCTION MANUAL 3 16 Minamiyakata Sakae Toyoake Aichi 470 1194 Japan ...

Страница 2: ...rdance with current regulations according to the manufacturer s instructions This electrolyzer is not intended for outdoor use including under canopy Exposure to rain may cause electric leak or shock Direct sunlight can damage the plastic tank exterior resulting in cracks and water leaks Ensure adequate ventilation Hydrogen gas or chlorine gas may cause health problems Do not mix electrolyzed wate...

Страница 3: ...Acid HOCl Sodium Hydroxide NaOH Cathode RED Anode OX Positive ions drawn to cathode Cl Negative ions drawn to anode Salt Water NaCl Diaphragm Electrolytic Cell Flow of electrons Cl H2O H2O Na Na Na Na Na OH OH 2e 2e H2 HOCl Reactions at Anode Chloride ions Cl and hydroxide ions emit electrons e to the anode which become hypochlorous acid HOCl Reactions at Cathode Sodium ions Na receive electrons e...

Страница 4: ...stored in the tank 2 Tank level lamp green Indicates the water level for each tank in three steps Electrolyzed water is not available if this lamp is off 3 Flush reverse dispense lamp blue The sanitizing and cleaning water outlets are switched while this lamp is on Check with the electrolyzed water lamp 4 Replace cell lamp red Flashes when the electrolytic cell needs to be replaced 5 Error lamp re...

Страница 5: ...um chloride KCl with more than 99 purity Any other kind of salt may cause failure clogged pipes or health problems 2 To prevent corrosion do not spill salt 3 Tightly close the salt chute door to avoid dust and dirt that may cause failure Blue line Salt chute Salt net Check the add neutralizer lamp on the operation panel If it is flashing follow steps 1 to 4 below 1 Uncap the neutralizer Add in neu...

Страница 6: ...mp cloth IMPORTANT 1 Do not damage the stainless steel surfaces Use of a steal brush or steel wool may break oxide film to develop corrosion inside 2 Use a calcium chloride based liquid cleanser to remove corrosion dirt and chlorides 3 Clean the stainless steel surfaces along with their grains if any b CLEANING WATER CIRCUIT MONTHLY The cleaning water circuit has calcium and magnesium deposits Con...

Страница 7: ...ipes reduction in performance or failure of the electrolytic cell If sampled water is hard contact an authorized Hoshizaki service company 1 Open the water sampling tap Let water run for more than 5 seconds Sample water in the measuring cup 2 Pour one or two drops of the water hardness indicator into the measuring cup and stir a little Check the water hardness red hard water blue soft water Water ...

Страница 8: ...OFF switch again to resume operation When one of the following error codes appears immediately contact an authorized Hoshizaki service company Lamp Code Problem Possible Cause Remedy Flash E14 Water valve defective Repair or replacement is required Contact an authorized Hoshizaki service company E31 Water valve salt water tank defective E53 Reversing relay defective E61 Flow switching valve defect...

Страница 9: ...ly 5 30 C Water Supply Comply with local water requirements Pressure 0 10 0 75MPa with pressure reducing valve Model ROX 60SA EW Electrolysis System Membrane technology Electrolyte Salt containing at least 99 sodium chloride Power Supply 1 phase 220 240V 50 60Hz Electric Consumption 460W Pump operation 760 890W Performance Standard Sanitizing water pH3 or less available chlorine 20 60mg kg Cleanin...

Страница 10: ...ntration Salt level Neutralizing agent level Water hardness Water leaks around unit Water leaks from water circuit Cell run time Checked by Sanitizing water only Date Time pH Sanitizing water Cleaning water Neutralizer Available chlorine concentration Salt level Neutralizing agent level Water hardness Water leaks around unit Water leaks from water circuit Cell run time Checked by Sanitizing water ...