VI. MAINTENANCE
1. CHECKING pH AND AVAILABLE CHLORINE CONCENTRATION
IMPORTANT
Be sure to check electrolytic water before use.
1) Dispense acid and alkaline water into glasses or other containers.
2) Use the Test Paper to check the following values:
Check Item
Applicable Test Paper
Acid Water pH Value
pH Tester TB
Alkaline Water pH Value
pH Tester AZY
Acid Water Available Chlorine Concentration
Chlorine Tester
Note: It is not necessary to check the available chlorine concentration of alkaline water.
3) Check that each value is within the following range:
Specified range for each value
pH
Available Chlorine Concentration
Acid Water
Approx. 2.7 or less
20-30mg/L or more
Alkaline Water
Approx. 11.3 or more
N/A
Note: See the Instruction Manual of each test paper for details of its proper handling. If any of
the checked values exceeds the specified range, contact an authorized Hoshizaki
service company. To order a new supply of test paper, contact an authorized Hoshizaki
service company.
4) Fill in a copy of the “VIII. DAILY INSPECTION SHEET” and keep a record of the checked
value.
2. FLUSHING ALKALINE WATER PIPE
IMPORTANT
Scale, such as calcium, magnesium, etc. forms inside the Alkaline Water Pipe.
The use of the alkaline pipe with scale for a long period of time may prevent the
flow of alkaline water, stop the unit or cause poor performance. To prevent scale
from accumulating, flush the Alkaline Water Pipe periodically.