10
III. INSTALLATION AND OPERATING INSTRUCTIONS
1.CHECKS BEFORE INSTALLATION
IMPORTANT
1. Remove shipping carton and tape(s). If packaging material is left in the water
electrolyzer, it will not work properly.
2. Use potable water. If water other than potable water is used, it may clog pipes,
cause poor performance, etc.
3. Purchase either the Remote Controller (Option) or Water Tank Float Switch
(Option).
4. Install a water softener and water filter (sold separately) on the water electrolyzer
to improve machine performance and prevent electrolytic cell damage, etc.
1) Be sure not to damage the panels when installing the water electrolyzer.
2) Remove the package containing the accessories.
3) See the Nameplate on the Rear Panel and check that the voltage supplied corresponds
with the voltage specified on the Nameplate.
2. HOW TO REMOVE PANELS
a) Rear Panel --------- Remove the screws.
Lift off slightly and pull toward you.
3. LOCATION
WARNING
1. This water electrolyzer is not intended for outdoor use. Normal operating ambient
temperature should be 40°F to 95°F (+5°C to +35°C); Normal operating
water temperature should be 40°F to 85°F (+5°C to +30°C). Operation
of the water electrolyzer for extended periods outside of these normal
temperature ranges may affect performance.
Fig. 2
Rear Panel
Содержание ROX-20TA-U