DISCONNECT UNIT FROM POWER SUPPLY BEFORE DOING ANY SERVICE
Instructions to Replace Compressor
21. Proceed to braze the
service, discharge and
suction tubing.
22. Place double sided tape
in the compressor
evaporation tray pan and
fix it over the compressor
applying slight pressure.
Accommodate the
discharge tubing into the
evaporation tray pan.
23. Follow slides # 21
through # 24 to
install the relay,
overload protector
and starting capacitor.
24. Braze the filter to the
condenser discharge line and to
the capillary tubing.
Do not over heat the body of the
filter and take great care not to
block the capillary tubes with
solder material. The filter dryer
must be installed in a vertical
position with the capillary tube
inlet at the bottom of the filter.
Содержание RM-26
Страница 1: ...SERVICE MANUAL FOR MODEL RM 26...
Страница 36: ......