DISCONNECT UNIT FROM POWER SUPPLY BEFORE DOING ANY SERVICE
Instruction to Replace Starting Relay, Overload Protector and Starting Capacitor.
9. First disconnect the two black wires connecting the
starting capacitor and the blue color wire of the start
relay. Then use a slotted screwdriver as a pry bar to pull
out the relay / overload protector assembly from the
compressor shell.
10. To install the new relay / overload protector assembly
reverse the previous steps.