Instruction to Replace Relay, Overload Protector and Starting Capacitor.
DISCONNECT UNIT FROM POWER SUPPLY BEFORE DOING ANY SERVICE
6. The condensing unit can be removed
all the way out for easier service.
8. At the same time that the plastic
electric box is being pushed
downward with the slotted
screwdriver, hold the box with the
other hand and pull it out
downward.
7. Insert a flat screwdriver in the slot of
the plastic electrical box to remove it
from the compressor. Use the flat
screwdriver as a pry bar to push the
box downward.