33
[5] Cabinet
Temperature
Too Low
a) Setpoint
1. Incorrect.
1. Correct setpoint.
Factory defaults:
Refrigerator 36°F (2°C).
b) Cabinet Thermistor
1. Defective.
1. Check and replace.
c) Evaporator Fan Motor
1. Defective.
1. Replace.
d) Control Board
1. Defective.
1. See "IV.B. Control Board Check."
2. Evaporator is Frozen Up
[1] Evaporator does
not defrost
completely.
a) Defrost Frequency
1. Not enough defrosts
occurring per day.
Operation in humid
conditions.
1. See "II.D.5. b) Defrost Frequency."
b) Defrost Thermistor
1. Out of position or defective.
1. Reposition or replace.
c) Control Board
1. Defective.
1. Replace.
[2] Compressor on
during defrost.
a) Compressor Relay
1. Bad Contacts.
1. Replace.
b) Control Board
1. Defective.
1. See "IV.B. Control Board Check."
3. Defrost Fails to Terminate
[1] Defrost cycle
too long.
a) Defrost Thermistor
1. Out of position or defective.
1. Reposition or replace.
b) Defrost Frequency
1. Not enough defrosts
occurring per day. Operation
in humid conditions.
1. See "II.D.5.b) Defrost Frequency."
c) Control Board
1. Defective.
1. See "IV.B. Control Board Check."
[2] Compressor
operates during
defrost.
a) Compressor Relay
1. Bad Contacts.
1. Replace relay.
b) Control Board
1. Defective.
1. Replace.
4. Other
[1] Abnormal Noise. a) Fasteners
1. Loose fasteners allow
vibration of part.
1. Tighten fasteners.
b) Compressor
1. Problem with mount or
electronic unit.
1. Properly mount compressor.
Replace any missing grommets.
2. Floodback to compressor.
2. Check for signs of floodback
to compressor. Evacuate and
recharge if necessary.
3. Defective.
3. Replace.
c) Fan (evaporator or
condenser)
1. Fan blade loose.
1. Adjust and tighten.
2. Defective motor.
2. Replace.
d) Relay
1. Chattering.
1. Replace.
[2] Condensate
water overflow.
a) Cabinet Contents
1. Loading of large volumes
of warm, moist, uncovered
product.
1. Allow product to cool before
placing in cabinet. Cover
product with plastic wrap.
b) Location of Unit
1. Unit located near high
humidity source such as
fryer, steamer, etc.
1. Relocate.
c) Seals
1. Poor sealing around
evaporator, door gaskets.
1. Adjust or replace.
d) Environment
1. Extreme environment and
door-opening conditions.
1. Adjust conditions.