16
Alarm Signals (continued)
Alarm
Code
No. of Beeps
(every 10 sec.) Problem
Reset Options
E9
Constant
Defrost Thermistor
During alarm, unit operates in the defrost
thermistor fail mode.
Defrost Thermistor Fail Mode: Defrost occurs
once every 6 hours and terminates after
45 minutes.
After replacing thermistor, alarm
resets.
During alarm, press the display board
"RESET" button to silence alarm for
5 minutes.
E10
10
N/A [Dual Temp Models Only] Communication
error between control boards.
N/A
CF
1
Clogged Filter Alarm (condenser thermostat)
Condenser filter needs cleaning.
WARNING: If this alarm occurs frequently,
discharge temperature is consistently too
high. Failure to take action could result in
damage to the compressor.
Clean filter. Allow time for thermostat
to react, then press the display board
"RESET" button.
During alarm, press the display board
"RESET" button to silence alarm for
2 hours.
door
2
Door open: Display alternates between cabinet
temperature and "door."
Door open longer than 3 minutes: alternating
display continues and alarm sounds.
Close door. During alarm, press
the display board "RESET" button
to temporarily silence alarm for
3 minutes.
Note: Setting service menu item #3 to "ON" resets all alarms regardless of whether
or not the problems are resolved. This is a complete clearing of all alarms. See
"II.D.6. Service Menu" for details.