C. Setup
1. Remove the Unit from the Pallet and Remove the Plastic Film
1) Move as close to the final location as possible.
2) Remove the bolts that secure the cabinet to the pallet. Using safe lifting practices, slide
the unit forward from the pallet and gently lower it to the floor. Do not allow doors or
drawers to bear the weight of the unit when lowering.
3) Remove the protective plastic film from the exterior and interior, including the rail cover.
If the unit has been exposed to the sun or to heat, remove the film after the unit cools.
2. Install the Rail Condensate Pan
Slide the rail condensate pan into place on the
brackets under the front of the unit. See Fig. 1. Make
sure the pan contacts the rear stops.
Rail Condensate Pan
Fig. 1
3. Check the Refrigeration Circuit
1) Visually check that the refrigerant lines do not rub or touch other lines or surfaces and
that the condenser fan blade and rail fan blades turn freely.
2) Check that the compressor is snug on all mounting pads.
4. Position the Unit and Lock the Front Casters
The front casters on the unit are lockable. After positioning the unit in its final location,
lock the front casters.
5. Install the Shelves (if applicable)
Shelf support clips are provided in the accessory pack.
1. Place the shelf support clips into the pilasters and air
duct (4 shelf support clips per shelf). See Fig. 2.
2. Place the shelves in position on the shelf support
clips.
Fig. 2
Shelf
Support
Clip
Air Duct
Shelf