31
No Ice Production - Possible Cause
13. Inlet Water Valve
a) Screen or orifice clogged.
b) Coil winding open.
c) Water valve open in freeze cycle.
14. Float Switch
See "II.F. Float Switch Check and
Cleaning"
a) Float does not move freely.
b) Defective.
15. Compressor
a) Magnetic contactor contacts bad or coil winding open.
b) Start capacitor or run capacitor defective (1 phase SRK).
c) Start relay contacts bad or coil winding open
(1 phase SRK).
d) Internal protector open.
e) Compressor defective.
16. Hot Gas Valves (KMS & SRK)
a) Closed in harvest cycle.
b) Open in freeze cycle.
17. Thermistor
See "II.G. Thermistor Check"
a) Loose, disconnected, or defective.
18. Pump Motor
a) Motor winding open.
b) Bearing worn out or locked rotor.
c) Defective capacitor.
19. Thermostatic Expansion Valve
a) Bulb loose.
b) Operating erratically.
20. Liquid Line Valves (KMS & SRK) a) Closed in freeze cycle.
b) Open in harvest cycle.
21. Fan Motors-Remote
a) Magnetic contactor contacts bad or coil winding open.
b) Motor winding open.
c) Bearing worn out or locked rotor.
d) Defective capacitor.
22. Headmaster
a) Defective.
23. Water System
a) Water leaks causing short freeze time.