![Hoshizaki KMS-1122MLJ Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/hoshizaki/kms-1122mlj/kms-1122mlj_service-manual_2164837026.webp)
26
F. Float Switch Check and Cleaning
FS is used to confirm sufficient water in the water tank after the 1-min. fill cycle and
after each harvest cycle. FS is also used to terminate the freeze cycle. No adjustment is
required.
1. Float Switch Check
To check FS, follow the steps below.
1) Turn off the power supply.
2) Remove the front panel.
3) Place the control switch in the "SERVICE" position. Then place the service switch in the
"DRAIN" position.
4) Replace the front panel in its correct position, then turn on the power supply for 2 min.
5) Turn off the power supply.
6) Remove the front panel, then move the control switch to the "OFF" position.
7) Remove the control box cover, then disconnect FS connector from CB black
K5 connector.
8) Check for continuity across FS leads. With the water tank empty, FS should be open.
If open, continue to step 9. If closed, follow the steps in "II.F.2. Float Switch Cleaning."
After cleaning FS, check it again. Replace if necessary.
9) Reconnect FS connector to CB black K5 connector, then replace the control box cover
in its correct position.
10) Move the control switch to "ICE" position. Replace the front panel.
11) Turn on the power supply.
12) As water fills the water tank, FS contacts should close. After 1 min., the 1-min. fill cycle
should end and the initial harvest cycle should begin. If harvest cycle doesn't start after
1 min. check continuity of FS with water tank full. If open, replace FS. If closed and
harvest cycle has not started, replace CB.
13) Once the harvest cycle starts, turn off the power supply.
14) Remove the front panel, then move the control switch to the "OFF" position.
15) Remove the control box cover, then disconnect FS connector from CB black
K5 connector.
16) Check for continuity across FS leads. With the water tank full, FS should be closed.
If FS is closed and the appliance will not switch from the 1-min. fill cycle to the initial
harvest cycle, replace CB.
17) If open, confirm that the water tank is full. If the water tank is not full, check the water
supply, water filters, and inlet water valve. If the water tank is full, follow the steps in
"II.F.2. Float Switch Cleaning." After cleaning FS, check it again. Replace if necessary.
18) Reconnect FS connector to CB black K5 connector, then replace the control box cover
in its correct position.