4. MECHANICAL BIN CONTROL
(THESE INSTRUCTIONS NOT APPLICABLE TO MODELS WITH THERMOSTAT)
[a] PROXIMITY SWITCH
1) This machine uses a lever-actuated proximity switch (hereafter called “mechanical bin
control”) to control the ice level in the storage bin.
[b] EXPLANATION OF OPERATION
1) The startup and shutdown of the ice machine is controlled via the controller board.
Dip Switch number seven must be in the ON position for the controller board to re-
ceive input from the bin control.
(i) The controller board receives a resistance value input via the red K4 connector
from the bin control. A resistor wire harness is connected from the bin control to
the controller board.
(ii) When the bin control is activated in the bin full position (pushed to the right), a
15.8 K
Ω
signal will be sent to the control board to shut down the unit.
(iii) When the bin control is in the normal position (bin is not full), a 7.9 K
Ω
reading is
sent to the control board to continue operation.
2) During operation, the controller board will only shut down the machine if a 15.8 K
Ω
signal is received from the bin control during the first 5 minutes of the freeze cycle.
(i) If ice pushes the lever to the right after the first five minutes of the freeze cycle,
the controller board will allow the machine to complete the freeze cycle and the
following harvest cycle before shutting down the machine. This will prevent
incomplete batches of ice from forming on the evaporator.
(ii) If the sensor detects ice within ½ inch of the face and energizes the bin control
relay during the harvest cycle, the controller board will allow the machine to
complete the harvest cycle before shutting down the machine. This will ensure
that all ice has been removed from the evaporator before shutting the machine
down.
Содержание KML "F" SERIES
Страница 6: ...6 I SPECIFICATIONS 1 KML 250MAH...
Страница 7: ...7 2 KML 250MWH...
Страница 8: ...8 3 KML 350MAF...
Страница 9: ...9 4 KML 350MWF...
Страница 10: ...10 5 KML 350MAH...
Страница 11: ...11 6 KML 350MWH Beginning serial L00001J ending Serial M20060C...
Страница 12: ...12 7 KML 350MWH Beginning serial M30061E...
Страница 13: ...13 8 KML 450MAF...
Страница 14: ...14 9 KML 450MWF...
Страница 15: ...15 10 KML 450MAH...
Страница 16: ...16 11 KML 450MWH Beginning Serial L00001D ending Serial M10530B...
Страница 17: ...17 12 KML 450MWH Beginning Serial M20531D...
Страница 18: ...18 13 KML 600MAF...
Страница 19: ...19 14 KML 600MWF...
Страница 20: ...20 15 KML 600MRF...
Страница 21: ...21 16 KML 600MAH...
Страница 22: ...22 17 KML 600MWH Beginning Serial L00001D ending Serial M10115C...
Страница 23: ...23 18 KML 600MWH Beginning Serial M10121E...
Страница 24: ...24 19 KML 600MRH...
Страница 25: ...25 20 CONDENSER UNIT URC 7F Unit mm inches...
Страница 26: ...26 SPECIFICATIONS URC 7F...
Страница 48: ...48 b KML 250MWH KML 350MWF KML 350MWH KML 450MWF KML 450MWH KML 600MWF KML 600MWH...
Страница 49: ...49 c KML 600MRF KML 600MRH...
Страница 65: ...65 4 PERFORMANCE DATA a KML 250MAH...
Страница 66: ...66 b KML 250MWH...
Страница 67: ...67 c KML 350MAF...
Страница 68: ...68 d KML 350MWF...
Страница 69: ...69 e KML 350MAH...
Страница 70: ...70 f KML 350MWH Serial L00001J through M20060C...
Страница 71: ...71 g KML 350MWH Beginning Serial M30061E...
Страница 72: ...72 h KML 450MAF...
Страница 73: ...73 i KML 450MWF...
Страница 74: ...74 j KML 450MAH...
Страница 75: ...75 k KML 450MWH Serial L00001D through M10530B...
Страница 76: ...76 l KML 450MWH Beginning Serial M20531D...
Страница 77: ...77 m KML 600MAF...
Страница 78: ...78 n KML 600MWF...
Страница 79: ...79 o KML 600MRF...
Страница 80: ...80 p KML 600MAH...
Страница 81: ...81 q KML 600MWH Serial L00001D through Serial M10115C...
Страница 82: ...82 r KML 600MWH Beginning Serial M10121E...
Страница 83: ...83 s KML 600MRH...