38
C. Settings and Adjustments
NOTICE
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact your
Hoshizaki Service Center.
1. Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
S4 Dip Switch
S4 Dip Switch No.
1
2
3
4
5
6
7
8
9
10
KMH-2100SWJ3
KMH-2100SRJ3
OFF OFF OFF OFF OFF OFF ON OFF ON OFF
KMH-2100SRJ
OFF OFF OFF OFF ON OFF ON OFF OFF OFF
S5 Dip Switch (Do Not Adjust)
S5 Dip Switch No. 1
2
3
4
5
All
OFF OFF OFF OFF ON
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5)
Pump-Out Time (3 & 4)
Harvest Timer (1 & 2)
Factory Use (8)
Harvest Pump Time (Harvest Assist) and Freeze-Time Correction (7)
(Do Not Adjust)
1
2
3
4
5
6
7
8
9
10
ON
S4 Dip Switch
1
2
3
4
5
ON
S5 Dip Switch
(
Do Not Adjust)
Refill Counter (2 and 3)
Float Switch Selector (1)
Minimum Harvest Time (4)
Anti-Slush (5)
Harvest Pump Time Timer (Harvest Assist Duration) (6)