55
3. KMH-2100SRJ3
Specification Sheet
AC SUPPLY VOLTAGE
208-230/60/3
AMPERAGE
12.5 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
2970 (3.70)
2700 (3.20)
WATER gal./24HR (gal./100 lbs.)
289 (15.0)
575 (28.4)
ICE PRODUCTION PER CYCLE
43.2 lbs. (19.6 kg) 2160pcs.
BIN CONTROL SYSTEM
Thermostat
REFRIGERANT CHARGE
TOTAL R404A, 16 lb. 1.5 oz. (7300g)
ICEMAKER, 8 lb. 6 oz. (3800g)
CONDENSER, 7 lb. 11.5 oz. (3500g)
Performance Data Sheet
70/21
2026
919
1996
906
1859
843
80/27
2003
909
1957
888
1766
801
90/32
1996
906
1925
873
1753
795
lbs./day kg./day
100/38
1936
878
1885
855
1595
723
70/21
80/27
90/32
watts
100/38
70/21
575
2.18
491
1.86
445
1.68
80/27
511
1.94
381
1.44
372
1.41
90/32
491
1.86
289
1.09
263
1.00
gal./day m
3
/day
100/38
394
1.49
283
1.07
239
0.91
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
222
15.6
234
16.4
248
17.5
80/27
231
16.2
249
17.5
263
18.5
90/32
234
16.4
262
18.4
277
19.4
PSIG kg/cm
2
G
100/38
236
16.6
265
18.7
290
20.4
70/21
50
3.5
51
3.6
52
3.7
80/27
50
3.5
51
3.6
53
3.7
90/32
51
3.6
52
3.7
54
3.8
PSIG kg/cm
2
G
100/38
51
3.6
52
3.7
55
3.9
22,900 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
CONDENSER VOLUME
214 CU. IN.
(URC-22F)
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
APPROXIMATE ELECTRIC
CONSUMPTION
2700
2779
2863
2760
2883
2954
2779
2970
3048
2788
2988
3120
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
26
27
31
27
28
34
27
30
35
29
31
40
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
5.0
4.3
4.1
4.5
3.4
3.6
4.3
2.6
2.6
3.6
2.6
2.7
HEAD PRESSURE
SUCTION PRESSURE
ENG.F-011.1.0205