79
[b] Sanitizing Procedure - Following Cleaning Procedure
1) Dilute a 5.25% sodium hypochlorite solution (chlorine bleach) with water (Add approxi-
mately 1.25 fl. oz. to 2.5 gal. of water).
2) Remove the insulation panel by removing thumbscrew, lifting up the panel slightly and
pulling it toward you.
3) Pour the sanitizing solution into the water tank.
4) Replace the insulation panel and the front panel in their correct positions.
Note: Make sure that the control switch is in the “WASH” position and the cleaning valve
is open.
5) Turn on the power supply, and start the sanitizing process.
6) Turn off the power supply after 15 minutes.
7) Remove the front panel.
8) Remove the insulation panel by removing thumbscrew, lifting up the panel slightly and
pulling it toward you. Remove cube guide B by removing thumbscrew. Remove cube guide
A. Remove overflow cap, overflow pipe, and water shield.
9) Remove the drain plug located inside the water tank. Drain the water tank. Replace the drain
plug in its correct position.
10) Replace water shield, overflow pipe, overflow cap, cube guide A, cube guide B, and
insulation panel in their correct positions.
11) Repeat the above steps 16) through 29) in “[a] Cleaning Procedure” two times to rinse
thoroughly.
12) Close the cleaning valve.
13) Move the control switch to the “ICE” position.
14) Replace the front panel in its correct position.
15) Clean the storage bin/dispenser unit with water.
16) Turn on the power supply, and start the automatic icemaking process.
Содержание KMD-700MAH
Страница 11: ...11 7 Condensing Unit URC 12F...
Страница 34: ...34 b KMD 700MWH and KMD 900MWH Note KMD 900M_H models have two expansion valves...
Страница 35: ...35 c KMD 700MRH and KMD 900MRH Note KMD 900M_H models have two expansion valves...
Страница 38: ...38 b1 KMD 700MRH auxiliary code R 0 and earlier Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0...
Страница 39: ...39 b2 KMD 700MRH auxiliary code R 1 and later Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0...
Страница 42: ...42 Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0 d1 KMD 900MRH auxiliary code R 0 and earlier...
Страница 43: ...43 d2 KMD 900MRH auxiliary code R 1 and later Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0...
Страница 75: ...75 Fig 5 Top View Drain Plug Water Shield Overflow Cap Overflow Pipe Cube Guide A Cube Guide B...