VI. Cleaning and Maintenance Instructions
1. Preparing the Icemaker for Long Storage
IMPORTANT
When shutting off the icemaker for an extended time, drain out all water from
the water line and remove the ice from the storage bin. The storage bin
should be cleaned and dried. Drain the icemaker to prevent damage to the
water supply line at sub-freezing temperatures, using a foot or hand pump.
Shut off the icemaker until the proper ambient temperature is resumed.
•
When the icemaker is not used for two or three days, it is sufficient to only move the control
switch to the “OFF” position, unless the icemaker will be at sub-freezing temperatures.
[1] On water-cooled models only, first remove the water from the water-cooled condenser:
1) Remove the front panel.
2) Move the control switch on the control box to the “OFF” position.
3) Wait 3 minutes.
4) Move the control switch to the “ICE” position.
5) Allow 5 minutes for the icemaker to fill with water and the water pump to start
operating.
6) Close the water-cooled condenser water supply line shut-off valve.
7) Open the drain valve for the water-cooled condenser water supply line.
8) Allow the line to drain by gravity.
9) Attach compressed air or carbon dioxide supply to the condenser water line drain valve.
10) Blow the water-cooled condenser out using compressed air or carbon dioxide until
water stops coming out.
Содержание KMD-700MAH
Страница 11: ...11 7 Condensing Unit URC 12F...
Страница 34: ...34 b KMD 700MWH and KMD 900MWH Note KMD 900M_H models have two expansion valves...
Страница 35: ...35 c KMD 700MRH and KMD 900MRH Note KMD 900M_H models have two expansion valves...
Страница 38: ...38 b1 KMD 700MRH auxiliary code R 0 and earlier Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0...
Страница 39: ...39 b2 KMD 700MRH auxiliary code R 1 and later Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0...
Страница 42: ...42 Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0 d1 KMD 900MRH auxiliary code R 0 and earlier...
Страница 43: ...43 d2 KMD 900MRH auxiliary code R 1 and later Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0...
Страница 75: ...75 Fig 5 Top View Drain Plug Water Shield Overflow Cap Overflow Pipe Cube Guide A Cube Guide B...