55
VI. MAINTENANCE AND CLEANING INSTRUCTIONS
IMPORTANT
Ensure all components, fasteners and thumbscrews are securely in place after
any maintenance or cleaning is done to the equipment.
1. PREPARING THE ICEMAKER FOR LONG STORAGE
WARNING
When shutting off the icemaker for an extended time, drain out all water
from the water tank and remove the ice from the Storage Bin. The
Storage Bin should be cleaned and dried. Drain the icemaker to prevent
damage to the water supply line at sub-freezing temperatures, using air or
carbon dioxide. Shut off the icemaker until the proper ambient tempera-
ture is resumed.
• When the icemaker is not used for two or three days, it is sufficient to only move the
Control Switch to the “OFF” position, unless the icemaker will be at sub-freezing
temperatures.
[1] On water-cooled model only, first remove the water from the water-cooled condenser:
1) Remove the Front Panel.
2) Move the Control Switch, on the Control Box, to the “OFF” position.
3) Wait 3 minutes.
4) Move the Control Switch to the “ICE” position.
5) Allow 5 minutes for the icemaker to fill with water and the Water Pump to start
operating.
6) Close the Water-cooled Condenser Water Supply Line Shut-off Valve.
7) Open the Drain Valve for the water-cooled condenser water supply line.
8) Allow the line to drain by gravity.
9) Attach compressed air or carbon dioxide supply to the Condenser Water Line Drain
Valve.
10) Quickly blow the water-cooled Condenser out, using compressed air or carbon
dioxide until water stops coming out.
Содержание KM-630MAF
Страница 6: ...6 2 KM 630MWF We reserve the right to make changes in specifications and design without prior notice ...
Страница 7: ...7 3 KM 630MRF We reserve the right to make changes in specifications and design without prior notice ...
Страница 11: ...11 b KM 630MWF ...
Страница 12: ...12 c KM 630MRF ...
Страница 25: ...25 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT a KM 630MAF ...
Страница 26: ...26 b KM 630MWF ...
Страница 27: ...27 c KM 630MRF ...
Страница 28: ...28 2 WIRING DIAGRAMS a KM 630MAF and KM 630MWF Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0 ...
Страница 29: ...29 b KM 630MRF U1GMA0179608 Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0 ...