6
2a. KM-500MWH
Serial #L00001D - M20960C
Note: We reserve the right to make changes in specifications and design without prior notice.
AC SUPPLY VOLTAGE
115/60/1
AMPERAGE
10 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
lbs./day ( kg/day )
70
*463 (210)
448 (203)
423 (192)
Reference without *marks
80
451 (205)
428 (194)
401 (180)
90
448 (203)
*411 (186)
385 (175)
100
442 (200)
405 (184)
361 (164)
SHAPE OF ICE
Crescent Cube
ICE PRODUCTION PER CYCLE
9.5 lbs. ( 4.3 kg ) 480 pcs.
APPROXIMATE STORAGE CAPACITY
N/A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
1130 (6.6)
1100 (5.7)
WATER gal./24HR (gal./100 lbs.)
135 (32)
245 (52.8)
WATER COOLED CONDENSER
723 (176)
380 (82)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)
22" x 27-3/8" x 30-5/16" (560 x 695 x 770 mm)
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear)
WEIGHT
Net 146 lbs. ( 66 kg ), Shipping 170 lbs. (77 kg.)
CONNECTIONS - ELECTRIC
Permanent - Connection
- WATER SUPPLY
Inlet 1/2" FPT
Condenser Inlet 1/2" FPT
- DRAIN
Outlet 3/4" FPT
Condenser Outlet 3/8" FPT
3/8" OD Pipe
CUBE CONTROL SYSTEM
Float Switch
HARVESTING CONTROL SYSTEM
Hot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROL
Timer Controlled. Overflow Pipe
COOLING WATER CONTROL
Pressure Regulator
BIN CONTROL SYSTEM
Proximity Switch with Delay
COMPRESSOR
Hermetic, Model AKA9455ZXA
CONDENSER
Water-cooled, Tube in tube type
EVAPORATOR
Vertical type, Stainless Steel and Copper
REFRIGERANT CONTROL
Thermostatic Expansion Valve
REFRIGERANT CHARGE
R-404A,
13.2 oz. ( 375 g )
DESIGN PRESSURE
High 427 PSIG, Low 230 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-out ( Internal )
COMPRESSOR PROTECTION
Auto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch
ACCESSORIES -SUPPLIED
N/A
-REQUIRED
Ice Storage Bin
OPERATING CONDITIONS
VOLTAGE RANGE
104 - 127 V
AMBIENT TEMP.
45 -100° F
WATER SUPPLY TEMP.
45 - 90° F
WATER SUPPLY PRESSURE
10 - 113 PSIG
Содержание KM-500MAH
Страница 28: ...28 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT a KM 500MAH ...
Страница 29: ...29 b KM 500MWH ...
Страница 30: ...30 c KM 500MRH ...
Страница 32: ...32 KM 500MAH with auxiliary codes M 2 and after and KM 500MWH with auxiliary codes M 4 and after ...
Страница 34: ...34 b KM 500MRH with auxiliary codes M 2 and after ...
Страница 35: ...35 3 TIMING CHART ...
Страница 36: ...36 ...