61
8. KM-650MRJ with URC-5F
Specification Sheet
AC SUPPLY VOLTAGE
115/60/1
AMPERAGE
16.1 A
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
1230 (5.25)
1150 (4.36)
WATER gal./24HR (gal./100 lbs.)
85 (15.0)
191 (30.3)
ICE PRODUCTION PER CYCLE
11.3 lbs. (5.1 kg) 480pcs.
BIN CONTROL SYSTEM
Mechanical Switch
REFRIGERANT CHARGE
TOTAL R404A, 4 lb. 4.8 oz. (1950g)
ICEMAKER, 2 lb. 6.8 oz. (1100g)
CONDENSER, 1 lb. 14 oz. (850g)
Performance Data Sheet
70/21
632
287
612
278
574
260
80/27
617
280
586
266
541
246
90/32
612
278
564
256
521
236
lbs./day kg./day
100/38
601
272
554
251
482
219
70/21
80/27
90/32
watts
100/38
70/21
191
0.72
160
0.61
145
0.55
80/27
168
0.63
119
0.45
119
0.45
90/32
160
0.61
85
0.32
78
0.30
gal./day m
3
/day
100/38
125
0.47
83
0.31
72
0.27
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
230
16.2
234
16.5
266
18.7
80/27
233
16.4
240
16.8
286
20.1
90/32
234
16.5
244
17.2
285
20.0
PSIG kg/cm
2
G
100/38
249
17.5
254
17.8
322
22.6
70/21
50
3.5
50
3.5
52
3.7
80/27
50
3.5
51
3.6
53
3.7
90/32
50
3.5
51
3.6
53
3.7
PSIG kg/cm
2
G
100/38
51
3.6
51
3.6
55
3.9
10,200 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
1,500 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
2.6
2.0
2.0
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
3.6
3.1
3.0
3.2
2.5
2.6
3.1
2.0
2.0
26
23
25
27
23
26
29
1175
1235
1270
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
22
23
25
23
24
APPROXIMATE ELECTRIC
CONSUMPTION
1150
1173
1197
1168
1204
1223
1173
1230
1251
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
ENG.F-011.1.0205