9
6. Electrical Connection
WARNING
1. Electrical connection must meet national, state,
and local electrical code requirements. Failure
to meet these code requirements could result in
death, electric shock, serious injury, fire, or severe
damage to equipment.
2.
THE REMOTE CONDENSER UNIT MUST BE
GROUNDED (EARTHED).
Install a proper ground
(earth) wire from the icemaker's fan motor junction
box terminal block to the remote condenser
unit's terminal block. See Fig. 14. Use wire of an
appropriate gage and outdoor rating. Failure to
properly ground (earth) the unit could result in
death or serious injury.
3. Install line and neutral wires from the icemaker's
fan motor junction box terminal block to the remote
condenser unit's terminal block. Use wire of an
appropriate gage and outdoor rating.
4. If a power supply cord is used instead of conduit
to connect the icemaker to the remote condenser
unit, this cord should be rated for outdoor use. A
certified strain relief (gland) rated IPX4 should be
used where the cord enters the remote condenser
unit.
5. Do not connect the remote condenser unit to an
external power source.
6. To reduce the risk of electric shock, make all
remote condenser unit connections before
connecting the icemaker power supply.
7. On remote air-cooled models, the icemaker should
have power for a minimum of 4 hours prior to
startup to prevent compressor damage.
Fig. 14
Wire Color Code:
BR–brown
GR/Y–green-and-yellow
V–violet
W–white
• Usually an electrical permit and services of a licensed
electrician are required.
• The opening for the power supply connection is 7/8"
(22 mm) DIA to fit a 1/2" trade size conduit.
1) Remove the louver panel.
2) Remove the icemaker's fan motor junction box cover.
Remove the remote condenser unit's junction box cover.
3) Install a ground (earth) wire from the icemaker's
fan motor junction box terminal block to the remote
condenser unit's terminal block. Use wire of an
appropriate gage and outdoor rating.
4) Install line and neutral wires from the icemaker's
fan motor junction box terminal block to the remote
condenser unit's terminal block. Use wire of an
appropriate gage and outdoor rating.
WARNING! The
remote condenser unit fan motors operate on
115VAC. DO NOT connect the remote condenser
unit to the 230VAC mains power supply.
5) Replace the junction box covers and the louver panel in
their correct positions.
Icemaker
Fan Motor Junction Box Cover
Neutr
al (N)
Line (L)
W
V
GR/Y
Junction Box 7/8" (22.2 mm)
Diameter Opening
Remote Condenser Unit
Louver Panel Junction Box Cover
Junction
Box
7/8" (22.2 mm)
Diameter Opening
Neutr
al (N)
Line (L)
Gr
ound (Ear
th)
W
BR
GR/Y
From Icemak
er:
Ground (Ear
th)
To Remot
e
Condenser Unit:
Terminal Block
Terminal Block
Содержание KM-1301S J-E Series
Страница 35: ...35 Intentionally Left Blank ...