ENGLISH
2
Fig. 4
Inlet Hose
Washer
Stop Valve
Fig. 3
Fig. 2
Downgrade
GOOD
NO GOOD
Upgrade
NO GOOD
Inlet Hose
Outlet Hose
Hose Adapter
* The main control box fuse is rated at 5AL 250V and should only be
replaced by a qualified service engineer.
* Usually an electrical permit and services of a licensed electrician are
required.
* If the supply cord and the plug should need to be replaced, it should
only be done by a qualified service engineer.
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in accordance with the
following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead of this appliance may
not correspond with the coloured markings identifying the terminals
in your plug, proceed as follows:
The wire which is coloured Green-and-Yellow must be connected to
the terminal in the plug which is marked with the letter E or by the
symbol or coloured Green or Green-and-Yellow. The wire which
is coloured Blue must be connected to the terminal which is marked
with the letter N or coloured Black. The wire which is coloured
Brown must be connected to the terminal which is marked with the
letter L or coloured Red.
* Should the socket outlets in the installation site not be suitable for
the plug supplied with your product, the plug must be removed (cut
off if it is moulded on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the power supply cord,
it must be disposed of. There should be no attempt to reuse it.
Inserting such a plug into a socket elsewhere presents a serious risk
of electrical shock.
* The non-rewirable plug must never be used without a fuse cover
being fitted.
The correct replacement for the detachable fuse cover is identifiable
from the manufacturer’s reference number stamped on the plug.
Supply of replacement fuse covers can be obtained from Hoshizaki
Parts/Service Centres.
Fuses should be rated at 0A and approved to BS 362.
5. WATER SUPPLY AND DRAIN CONNECTIONS
(For the U.K. only, the connections must be in accordance with current
requirements of the Model Water Byelaws 986 SI No. 47)
* Only potable water should be used for this icemaker.
* Water supply pressure should be minimum 0.7 bar and maximum 8
bar. If the pressure exceeds 8 bar, use a pressure reducing valve.
Do NOT throttle back the supply tap.
* Be sure to make connections with the new inlet and outlet hoses
provided, not with old used hoses.
* A plumbing permit and services of a licensed plumber may be
required in some areas.
* Water should drain into an open trap.
* The icemaker drain is gravity flow, so ensure drain pipe has an
adequate pitch or fall.
* To prevent a backflow into the Storage Bin, the outlet hose must be
laid as shown in Fig. 2.
) Attach the free end of inlet hose to the stop valve (Fig. 4), noting
washer is correctly positioned. Hand tighten sufficiently to provide
leak free joint. It is a wise precaution to have the stop valve within
easy reach.
2) Wrap P.T.F.E. tape around the hose adapter fitting, and screw the
hose adapter into the drain outlet of the icemaker. Hand tighten
grey flexible outlet hose (accessory) onto the hose adapter as
indicated (Fig. 3). The pipe can be cut to length as necessary to
suit position of main drain. To prevent water leaks, secure the
outlet hose to the drain outlet by using a hose band.
Note: Jointing compounds should be approved and suitable for
potable water use.