12
C. Display Module Icons
Display module icons inform you of energized components and if the appliance is in
alarm.
Display Module Icons
Icon
Meaning
Compressor
Steady: Compressor running.
Flashing:
•
Compressor delay timer. Compressor starts within 2 min.
•
While adjusting cabinet temperature setpoint. For cabinet temperature setpoint
adjustment, see "II.B Cabinet Temperature and Defrost."
Defrost
Appliance is in defrost cycle. See "II.F.3.10) Defrost" for details.
Evaporator Fan Motor
Evaporator fan motor is running. Evaporator fan motor de-energizes when door is open.
During energy saving mode, evaporator fan motor cycles with compressor. When compressor is
de-energized, evaporator fan motor cycles 1 min. on and 5 min. off.
Alarm
Appliance is in alarm. See "II.I. Alarm Safeties" for details.
D. Control Panel Lockout
The control panel can be locked to help prevent the appliance from being turned off or
the setpoint from being changed inadvertently.
To lock the control panel, press and hold the "-" button and the power button until "Loc"
appears briefly on the display module.
To unlock the control panel, press and hold the "-" button and the power button until
"UnL" appears briefly on the display module.