ENGLISH
11
IMPORTANT
When using the shelf at the bottom of the
cabinet, be sure to use the shelf holders to
prevent damage to the cabinet bottom, resulting
in corrosion.
6. ELECTRICAL CONNECTIONS
IMPORTANT
This refrigerator/freezer is provided with no
power switch or earth leakage circuit breaker,
but with overcurrent protection (fuse) only.
Install a switch rated at least 10A on the main
power supply.
* This refrigerator/freezer must be plugged into
the separated power receptacle which is readily
accessible and has enough capacity. The
maximum allowable voltage variation should not
exceed ± 10 percent of the nameplate rating. See
the nameplate.
* If the supply cord and the plug should need to be
replaced, it should only be done by a qualified
service engineer to avoid any danger.
7. DRAIN CONNECTIONS
1) Connect the accessory flexible hose with trap to
the drain outlet located at the bottom of the unit.
2) Use the accessory cable strap to fix the trap tightly
to the mounting hole on the bottom of the unit.
* The flexible hose may not be provided for some
models. If necessary, order the accessories
(3S1332A02).
IMPORTANT
1. To prevent disconnection, be sure to use the
cable straps to secure the flexible hose in
place.
2. The drain line should be as short and straight
as possible, sloped downward, and located
below the drain outlet.
3. To prevent backflow, do not connect the
flexible hose directly to the sewer system. An
air gap of at least 5 cm should be between
the end of the flexible hose and the floor
drain.
Flexible Hose
Water Surface
Min. 5cm
4. If the flexible hose is too short to reach the
floor drain, connect a commercial pipe to the
flexible hose. Be sure to allow an air gap of
at least 5 cm between the end of the drain
pipe and the floor drain.
Commercial Elbow
(not provided)
Water Surface
Min. 5cm
Commercial Pipe
20mm DIA
(not provided)
Fig. 8
5. The drain connections are required to
prevent ambient air from causing excessive
frost build up on the evaporator, resulting in
reduction of the refrigeration capacity.
6. Do not let water drain directly onto the floor
before running into the drain. Foreign matter
on the floor may mix into the water and clog
the drain, or the water could run in a wrong
direction.
Fig. 9
Cable Strap
Flexible Hose
Drain Outlet
(defrost water)