ENGLISH
4
[d] ELECTRICAL CONNECTIONS
WARNING
THIS APPLIANCE MUST BE EARTHED
This Remote Condenser Unit requires an earth
that meets the national and local electrical code
requirements. To prevent possible severe
electrical shock to individuals or extensive
damage to equipment, install a proper earth wire
to the icemaker.
* This Condenser Unit must be connected to the Fan
Motor leads in the Terminal Box on the icemaker.
* Use a lead with conductors of not less than 0.5 mm
2
cross section, having a vinyl sheath of “H05VV” or
higher grade.
* Protect the leads with a conduit.
* Usually an electrical permit and services of a licensed
electrician are required.
1) Remove the Panel.
2) Remove the Terminal Box Cover.
3) Connect the Fan Motor leads in the Terminal Box of
the Remote Condenser Unit to the Fan Motor leads
in the Terminal Box of the HOSHIZAKI remote air-
cooled icemaker.
4) Install an earth wire from the icemaker to the Remote
Condenser Unit.
5) Replace the Terminal Box Cover and the Panel in
their correct position.
(For the U.K. only, the connections must be in
accordance with current requirements of the Model
Water Byelaws 1986 SI No. 1147)
* Water supply pressure should be minimum 0.5 bar
and maximum 8 bar. If the pressure exceeds 8 bar,
use a proper pressure reducing valve. Do NOT throttle
back the supply tap.
* A plumbing permit and services of a licensed plumber
may be required in some areas.
* The icemaker drain is gravity flow, so ensure drain
pipe has an adequate pitch or fall.
* Water should drain into an open trap.
1) Attach angled end of white flexible inlet hose
(accessory) to the G3/4 fitting on the rear of the
icemaker as indicated, ensuring rubber sealing
washer is correctly positioned. Hand tighten
sufficiently to provide leak free joint.
2) Attach the other end of inlet hose to the water tap
(Fig. 10), noting washer is correctly positioned
before hand tightening as above.
3) Attach grey flexible outlet hoses (accessories) to
the R3/4 fittings as indicated, confirming fitment of
the rubber washers before finally hand tightening
the joints. These pipes can be cut to length as
necessary to suit the position of the mains drain.
4) The Storage Bin also has a drain which requires a
fitting and outlet pipe (not supplied). The three drains
must be separated to prevent a backflow from the
machine into the Bin.
Fig. 8
Fig. 9
Inlet Hose
Outlet Hose
Water Supply
Inlet G3/4
Overflow Drain
Outlet R3/4
Icemaking Water
Drain Outlet R3/4
Screw
Screw
Panel
Terminal Box Cover
6. WATER SUPPLY AND DRAIN
CONNECTIONS
WARNING
Only potable water should be used for the
icemaker.