No Ice Production - Possible Cause
Freeze Cycle
1. Control Board
See "II.C. Control Board Check."
a) Defective.
2. X3 Relay (C-0 and earlier) or
X12 Relay (C-1 and later)
a) Defective.
3. Start Relay/Capacitor
a) Defective.
4. Compressor
a) Open motor windings.
b) Mechanical Failure.
5. Fan Motor
a) Open motor windings.
b) Mechanical failure or fan blade binding.
6. Evaporator
a) Dirty.
b) Damaged or defective.
7. Refrigerant Charge
a) Low.
8. Drain Valve
a) Dirty, leaking by.
9. Water System
a) Water leaks.
10. Evaporator Heater
(-C model)
a) C-1 and later: X12 relay defective.
b) Defective.
Refill
1. Float Switch
See "II.E. Float Switch Check
and Cleaning."
a) Dirty/sticking.
b) Defective.
2. Inlet Water Valve
a) Screen or orifice clogged.
b) Defective.
3. Water Supply
a) Water supply off or improper water pressure (10 to 113 PSIG).
b) External water filters clogged.
4. X4 Relay (C-0 and earlier) or
X11 Relay (C-1 and later)
a) Defective.
5. Control Board
See "II.C. Control Board Check."
a) Defective.
Shutdown
1. Bin Control
See "II.D. Bin Control Check."
a) Proximity switch stuck closed.
b) Actuator paddle does not move freely.
2. X5 Relay (C-0 and earlier) or
X10 Relay (C-1 and later)
a) Defective.
3. Control Board
See "II.C. Control Board Check."
a) Defective.
Shutdown Drain Cycle
1. X3 Relay (C-0 and earlier) or
X12 Relay (C-1 and later)
a) Defective.
2. X5 Relay (C-0 and earlier) or
X10 Relay (C-1 and later)
a) Defective.
3. X4 Relay (C-0 and earlier) or
X11 Relay (C-1 and later)
a) Defective.
4. Control Board
See "II.C. Control Board Check."
a) Defective.
5. Drain Valve
a) Defective.