F. Diagnostic Tables
Before consulting the diagnostic charts, check for correct installation, proper voltage per
appliance nameplate, and adequate water supply. Check control board using the steps in
"II.C. Control Board Check."
1. No Ice Production
No Ice Production - Possible Cause
Startup
1. Power Supply
a) Unplugged, off, blown fuse, or tripped breaker.
b) Not within specifications.
2. Water Supply
a) Water supply off or improper water pressure (10 to 113 PSIG).
b) External water filters clogged.
3. Power Switch
a)
"OFF" position.
4. Control Transformer
(115V/24V)
a) Coil winding open or shorted.
5. Safety Switch (C-0 and earlier)
a) Engaged. Reset.
b) Defective.
6. X6 Relay (safety relay)
(C-0 and earlier)
a) Defective.
7. Fuse (1A)
a) Blown.
8. Bin Control
See "II.D. Bin Control Check."
a) Open.
b) Defective.
9. Flush/Control Switch
a)
In "FLUSH"
(C-0 and earlier) or
"DRAIN"
(C-1 and later) position.
b) Defective.
10. X5 Relay (C-0 and earlier) or
X10 Relay (C-1 and later)
a) Defective.
11. Evaporator Heater
(-C model)
a) C-0 and earlier: Defective.
Startup/Fill Cycle (reservoir empty)
1. X4 Relay (C-0 and earlier) or
X11 Relay (C-1 and later)
a) Defective.
2. Inlet Water Valve
a) Screen or orifice clogged.
b) Defective.
Startup/Ice Purge Cycle (reservoir full)
1. Float Switch
See "II.E. Float Switch Check
and Cleaning."
a) Float does not move freely.
b) Defective.
2. High-Pressure Switch
a) Dirty air filter or condenser.
b) Condenser fan motor defective.
c) Refrigerant overcharge.
d) Refrigerant lines or components plugged.
3. Control Board
See "II.C. Control Board Check."
a) Defective (#3 and #4).
4. X4 Relay (C-0 and earlier) or
X11 Relay (C-1 and later)
a) Defective.
5. Gear Motor
a) External or internal protector open.
b) Gear motor winding open.
c) Mechanical failure.