![Hoshizaki CM-50KE-HC Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/hoshizaki/cm-50ke-hc/cm-50ke-hc_original-installation-manual_2164947008.webp)
6
ENGLISH
* A plumbing permit and services of a licensed plumber may be required in some areas.
* The icemaker drain is gravity flow, so ensure drain pipe has an adequate pitch or fall.
* Drain lines should not be piped directly to the sewer system. A vertical air gap of a minimum of
5 cm should be between the end of the drain pipes from the icemaker and storage bin and the floor
drain.
* Be sure to use the new hose-sets supplied with the appliance. Do not reuse any old hose-sets.
1) Attach the angled end of white flexible inlet hose (accessory) to the G3/4 fitting on the top/bottom rear of the icemaker as
indicated, ensuring rubber sealing washer is correctly positioned. Hand tighten sufficiently to provide leak free joint.
2) Attach the other end of inlet hose to the water tap, noting washer is correctly positioned before hand tightening as above. It is
a wise precaution to have a stop valve within easy reach.
3) [FM-120/80KE-HC]
Hand tighten grey flexible outlet hose (accessory) onto the R3/4 fitting at the bottom rear of the icemaker as indicated,
ensuring rubber washer is correctly positioned to obtain a leak free joint. The pipe can be cut to length as necessary to suit
position of main drain.
[FM-60KE-HC, CM-50KE-HC]
Push grey flexible outlet hose (accessory) onto the push fitting at the bottom rear of the icemaker as indicated, ensuring hose
is correctly positioned to obtain a leak free joint and secure in position with clamp (accessory). The pipe can be cut to length
as necessary to suit position of main drain.
8. START-UP PROCEDURE
1) Check that the power supply cord is disconnected.
2) Move the operation switch on the operation panel to the “ON”
position.
3) Open the water supply tap.
4) Connect the power supply and energise.
5) The display will illuminate in the “ICE” mode.
6) The following should occur in sequence:
a) Water reservoir will fill.
b) Gear motor will start.
c) Compressor will start.
5cm air gap
Drain
Floor
Water Supply
Inlet G3/4
Inlet Hose
Drain Outlet
R3/4
Outlet Hose
[FM-120KE-HC, 80KE-HC]
[FM-60KE-HC, CM-50KE-HC]
Water Supply
Inlet G3/4
Inlet Hose
Drain Outlet
Outlet Hose
Water Supply Tap
Inlet Hose
Operation Panel
Ice Button
Display
Stop Button
Maintenance Button
(service use only)
Operation Switch