© 2003 Directed Electronics, Inc. Vista, CA
21
NOTE:
When adjusting the sensor, it must be mounted in the same location where it will be
after the installation is complete. Adjusting the sensor and then relocating the module may
require readjustment.
initializing the system
Before initializing the databus interface module, make sure that the power, ground, ignition and the databus
input wires are connected to the vehicle.
1. Cycle the ignition key on and then back off again.
2. Close all the vehicle doors.
3. Cycle the doors and trunk using the first OEM transmitter.
4. Repeat the door and trunk cycle for each transmitter programmed to the OEM keyless entry.
system features learn routine
The System Features Learn Routine dictates how the unit operates. It is possible to access and change any of the
feature settings using the Valet/program switch.
To enter the System Features Learn Routine:
1.
Open a door.
2.
Key.
Turn the ignition on, and then off. (The H1/9 YELLOW wire must be connected.)
3.
Select a feature:
Press and release the Valet/program switch the number of times corre-
sponding to the feature you wish to program. (See the following table of features.) For
example, to access the third feature, press and release three times. Then press the button
once more and
HOLD
it. The siren will chirp the number of times corresponding to the
feature you have accessed.