background image

SINGLE SIDED MODELS

700 Low Line              

700 Mk2 Pebble

700 Mk2 Coal

700 Ironbark Log Mk4

850 Low Line                      800 Mk2 Pebble

800 Mk2 Coal

850 Ironbark Mk4

1100 Low Line            

1000 Mk2 Pebble

1000 Mk2 Coal

850 Ironbark Log Mk4

1500 Low Line                    1400 Mk2 Pebble

1400 Mk2 Coal

2000 Low Line                    1800 Mk2 Pebble

1800 Mk2 Coal

SUITABLE GAS BURNER OPTION

CANTILEVER

700 Cantilever

700 Mk2 Pebble

700 Mk2 Coal

700 Ironbark Log Mk4

1100 Cantilever                    1000 Mk2 Pebble

1000 Mk2 Coal

850 Ironbark Log Mk4

DOUBLE SIDED MODELS

700 Low Line              

700 Mk2 Pebble

700 Mk2 Coal

700 Ironbark Log Mk4

850 Low Line                      800 Mk2 Pebble

800 Mk2 Coal

850 Ironbark Mk4

1100 Low Line            

1000 Mk2 Pebble

1000 Mk2 Coal

850 Ironbark Log Mk4

1500 Low Line                    1400 Mk2 Pebble

1400 Mk2 Coal

2000 Low Line                    1800 Mk2 Pebble

1800 Mk2 Coal

2

Natural Draft Electronic
Ignition approved for the 
following models

Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces

12

5mm

12

5mm

Location Requirements

Horizon natural draft electronic ignition fireplaces are 
designed to be installed as a complete fireplace 
system. The firebox incorporates a gas burner with 
electronic ignition and spiggot for attaching a flue. 
The flue needs to run vertically and exit above the 
roof line. 45 degree bends can be utilised. All A.G.A 
requirements for flues are to be observed when 
installing.

Ventilation Requirements:

Rooms with gas open fires require fresh air vents a 
per gas regulations. For example:

1 x VENT REQUIRED

430mm

2 x VENTS REQUIRED

270mm

Model Type 2: Natural Draft 
Electronic Ignition Gas Fireplace

DATA PLATE: Refer to data plate for information in 
respect to gas pressure, consumption and gas type, 
Natural or LPG.
Data Plate is located under the gas burner and is 
accessed
by lifting front access panel or removing base plate.

VENTILATION

: An opening to outside with a minimum 

free ventilation area of 400sq. centimetres for each 
decorative gas log fire.

NOTE: 

The chimney in which the appliance is not 

installed is not to be considered as a ventilation 
opening.

Содержание Natural Draft

Страница 1: ... FIREPLACES Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces ...

Страница 2: ...as Fireplaces 125mm 125mm Location Requirements Horizon natural draft electronic ignition fireplaces are designed to be installed as a complete fireplace system The firebox incorporates a gas burner with electronic ignition and spiggot for attaching a flue The flue needs to run vertically and exit above the roof line 45 degree bends can be utilised All A G A requirements for flues are to be observ...

Страница 3: ...ll gas fires be serviced every year All gas units must be fitted by a licensed gas fitter It is the responsibility of the gas fitter to follow the regulations set out in the Gas Code that dictate the procedures to follow when installing a gas appliance particularly regarding gas pipe sizing and checking of pressures Installation 1 The N D E I system is supplied with all required electrical fitting...

Страница 4: ...DOUBLE SIDED A B C D E F G H I 700 LOW LINE 700 270 450 670 1000 300 250 10 27 850 LOW LINE 850 270 450 770 1095 300 250 10 27 1100 LOW LINE 1100 275 450 770 1345 300 250 10 27 1500 LOW LINE 1500 290 435 900 1746 350 300 10 27 2000 LOW LINE 2000 290 435 900 2246 350 300 10 27 SINGLE SIDED A B C D E F G H I 700 LOW LINE 700 270 365 670 1000 228 176 10 15 850 LOW LINE 850 270 405 770 1095 247 225 10...

Страница 5: ...1796 490 510 980 1280 2000 LOW LINE 2293 490 510 980 1280 B INCLUDING 10mm PLASTERBOARD C INTERNAL FRAME HEIGHT WHEN USING HEAT ZONE KIT REFER TO HEAT ZONE CONVERSION PAGE SINGLE SIDED A B B C C 700 LOW LINE 1056 410 420 750 1050 850 LOW LINE 1145 450 460 845 1145 1100 LOW LINE 1408 450 460 845 1145 1500 LOW LINE 1796 480 490 950 1280 2000 LOW LINE 2293 480 490 950 1280 B INCLUDING 10mm PLASTERBOA...

Страница 6: ...200 MM MIN FAN 300MM x 105MM 137 MM OPTIONAL SECOND FAN TIMBER SUPPORT REQUIRED SPIRAL DUCT 150MM MAX WITH NO AIR POCKETS CANNOT BE VENTED UNDERNEATH UNIT INSULATION BOARD SECTION A A HEATZONE ACTIVE FLUE CASING STANDARD VENT HOLES FULL WELD ACCESS PANELS MUST BE INCORPORATED FOR SERVICING OF MECHANICAL COMPONENTS HEAT ZONE CONVERSION ...

Страница 7: ...ation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces HEAT ZONE CONVERSION Fireplace ON OFF Switch S1 Optional Heatzone ON OFF Switch S2 General Purpose Outlet GPO SW 2 SW 1 2 x10 amp GPO S ...

Страница 8: ...N GAS BURNER FRAMEWORK AND 10MM WALL LINING BY INSTALLER SELECTED FACING BY INSTALLER ELEVATION STAINLESS STEEL EDGE TRIM GLASS SIDE VENTILATION TO BURNERS FLOOR WALL SWITCH ON OFF SWITCH BURNER ISOLATING ELECTRICAL SWITCH 240 V PLUG WALL SWITCH ON OFF SWITCH BURNER ISOLATING ELECTRICAL SWITCH 240 V PLUG SINGLE SIDED CANTILEVER Installation Instructions Kemlan Natural Draft Electronic Ignition Gas...

Страница 9: ... off wall switch System does not have a high low burner switch Once the bottom layer is completed build up 2 3 tiers of coals in a honeycomb pattern to form an elongated pyramid Lay the coals pebbles so that some irregularity to the pile through which the flames may lick is created Your aim is to build windows into the fire through which the radiant effect may show but at the same time not leaving...

Страница 10: ...ES 1000 992 X 135 MARK 2 COALS 1400 1400 X 64 MARK 2 PEBBLES 1400 1400 X 64 MARK 2 COALS 1800 1800 X 64 MARK 2 PEBBLES 1800 1800 X 64 MARK 2 COALS 1000 992 X 135 MARK 2 PEBBLES 700 800 600 X 155 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces ...

Страница 11: ...rge log has two holes on the underside to position in place 1 L O C AT E 4 C E R A M I C C OA L S Four ceramic coals are supplied with the burner base These coals must be laid in the position indicated on the drawing with the taller coals on the ends and smaller coals in between 3 LOCATE LOG NO S 2 3 Two front log NO S 2 3 are supplied to fit into the space between the metal frame and the ceramic ...

Страница 12: ...right hand side of the burner on the rear log in front of the pilot Charred end facing inwards The left hand side of the log is positioned between the metal uprights on the side of the grate LOCATE LOG NO 7 The charred effect of the log is positioned on the smaller coal in the centre of the burner on the right hand side LOCATE LOG NO 8 This smaller log is placed on the top of log NO 2 and rests on...

Страница 13: ...en 3 LOCATE LOG NO S 2 3 Two front log no s 2 and 3 are supplied to fit into the space between the metal frame and the ceramic base These logs do not cover the front burner ports but are designed to deflect the front flame back into the fire L O G S P O S I T I O N I N G OF A L L L O G S It is important to follow the log recommended positioning Not doing so can adversely effect the operation of th...

Страница 14: ...t hand side of the burner with the right hand side of the logs positioned between the metal uprights of the grate Two pins are provided to firmly position these two logs onto the large rear log no 1 P O S I T I O N I N G O F A L L L O G S It is important to follow the log recommended positioning Not doing so can adversely effect the operation of the appliance This diagram shows the recommended log...

Страница 15: ...ay aerosols in the vicinity of this appliance whilst it is in operation DO NOT modify this appliance Primarily a decorative appliance not certified as a space heater 6 The appliance is a live fuel effect product designed to operate with luminous flames and may exhibit slight carbon deposition 7 The guard is fitted to this appliance to reduce the risk of fire or injury from burns and no part of it ...

Страница 16: ... For further service information contact Kemlan Australia Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Head Office 13 French Avenue Brendale Queensland 4500 Telephone PH 07 3490 5500 ...

Страница 17: ...CHECK FAN ON INDEPENDENT POWER SWITCH FAN COMES ON PILOT ON MAIN BURNER DOES NOT LIGHT 1 FLAME SENSOR NOT SENDING SIGNAL TO OPEN VALVE CHECK ELECTRODE IS IN PILOT FLAME CLEAN ELECTRODE CHECK ELECTRODE CONNECTIONS REPLACE ELECTRODE IF DAMAGED 2 MODULE NOT SENDING CHECK CONNECTIONS SIGNAL TO OPEN VALVE REPLACE MODULE 3 FAULTY VALVE REPLACE VALVE FLAME FAIL LOCKOUT UNIT HAS DETECTED LOSS OF FLAME AND...

Страница 18: ...GNAL TO OPEN VALVE FLAME CHECK ELECTRODE CONNETCTIONS CLEAN ELECTRODE CHECK ELECTRODE FOR DAMAGE REPLACE ELECRODE 2 MODULE NOT SENDING REPLACE MODULE SIGNAL TO OPEN VALVE 3 FAULTY VALVE REPLACE VALVE FLAME FAIL LOCKOUT 1 POWER FAILURE TURN ON OFF SWITCH OFF AND UNIT HAS DETECTED LOSS OF FLAME AND LOCKED OUT ON AGAIN TO RESET ONCE POWER ESTABLISHED 2 GAS SUPPLY CHECK GAS PRESSURE AND ADJUST RESET A...

Страница 19: ...ponents There is a red LED light and a green LED light on the blue ignition box If a fault occurs the sequence of the flashing red light indicates the fault These codes are listed below The green light indicated the ignition box is sensing the flame Fan Forced Models The codes above still apply plus the codes below Atmospheric Models Flash Code Meaning Possible Cause Red LED Long 1 short 0 Running...

Страница 20: ...y cause The fault code on the module red LED will be 2 long and 1 short Before carrying out repairs turn off the power visually inspect all cables and connections for damage or corrosion On start up once the unit has passed the self test and pressure switch is closed on fan forced models you should be able to hear a clunk from the gas valve as it opens If no sound from the gas valve check connecti...

Страница 21: ... 2 2 Lockout due to flame failure 2 3 Hardware failure on Combustion fan drive or microcontrollers disagree 2 4 Hardware failure on GAS1 valve drive or microcontrollers disagree 2 5 Hardware failure on GAS2 valve drive or microcontrollers disagree 2 6 Hardware failure on flame sensor 2 7 Relay Enable signal hardware failure stuck in ON state 3 1 Lockout due to pressure switch opening 3 2 Lockout d...

Отзывы: