Rinse off acid spatters in the eye or on the skin with plenty of clear water. Afterwards, consult a 
doctor immediately.
Wash acid-contaminated clothes with water.

Recycling.

Lead acid batteries which are not given to recycling have to be disposed of as hazardous waste 
in compliance with all regulations.

General instruction or instruction for the better understanding and the optimum use of the battery 
(batteries).

Pb

0 Symbols and Safety Instructions Used in this Documentation

The following safety instructions must be observed. The listed safety symbols are repeatedly used for safety-
relevant instructions in this documentation:

  Danger!

Danger to the health of persons, to the battery (batteries) or to the environment. 
Non-compliance with these hazard warnings can cause severe or fatal injuries.

  Danger!

Danger to the battery (batteries), objects or environment. Danger to persons is unlikely. Non-
compliance can cause failures of and damages to the battery (batteries). Moreover, material 
damage and environmental damage might occur.

Danger due to explosion, shock waves, hot or molten flying substances.
Risk of explosion and fire, avoid short circuits!
Electrostatic charges or discharges/sparks must be avoided!
Non-compliance with these hazard warnings can cause severe or fatal injuries.

Risk of chemical burns due to leaking electrolyte.
Electrolyte is highly corrosive!

Danger to the life and health of persons due to electrical potential.
Attention! Metal parts of the battery cells/blocks are always energized. 
Therefore, do not deposit foreign items or tools on the battery.
Non-compliance with such hazard warnings can cause severe or fatal injuries.

Warning against danger due to batteries.

No smoking!
No open flame, embers or sparks near the battery: risk of explosion and fire!

General prohibition.

Observe operating instructions and install them clearly visible in the battery room! Work on batte-
ries may only be carried out after instruction by specialist personnel.

Wear safety goggles and protective clothing when working with batteries!
Observe the accident prevention guidelines as well as DIN EN 50272-2 and DIN EN 50110-1!

Wear conductive footwear.

General prohibition.

Содержание grid aquagen pro

Страница 1: ...aquagen Assembly and operating manual grid aquagen pro grid aquagen pro max...

Страница 2: ...en the images in this documentation and the product you purchased Please keep this documentation at a place where it is always available to all persons carrying out work in connection with the batteri...

Страница 3: ...es of and damages to the battery batteries Moreover material damage and environmental damage might occur Danger due to explosion shock waves hot or molten flying substances Risk of explosion and fire...

Страница 4: ...neral Safety Instructions Danger The improper use of the products described here can lead to personal or material damage In case of improper use HOPPECKE assumes neither responsibility nor liability f...

Страница 5: ...m for lead batteries In compliance with the recycling management and waste management act the battery ordinance the transport permit ordinance as well as the guidelines of the general environment prot...

Страница 6: ...f protective clothing 1 4 3 Electrostatic Discharges All lead acid batteries develop hydrogen and oxygen gas known as oxyhydrogen during operation but mainly during charging These gases are escaping f...

Страница 7: ...le working on the batteries Danger Observe all aforementioned safety instructions and safety precautions in particular with regards to the leak resistances of gloves and safety boots see chap 1 3 as w...

Страница 8: ...aquagen from the battery the aquagen together with its bayonet plugs is loosened by turning it counter clockwise and then lifted off from the cell Figure 4 Loosening aquagen Figure 5 Lifting off aquag...

Страница 9: ...s of up to 2 6 V cell are reached Attention Before charging with voltages 2 4 V cell we recommend the removal of the aquagen recombi nators In order to avoid contaminations of the caps of the battery...

Страница 10: ...18 19 Assembly and operating manual aquagen 7149029926 V1 3 09 2018 Assembly and operating manual aquagen 7149029926 V1 3 09 2018 Notes Notes...

Страница 11: ...products are subject to constant development We therefore reserve the right to make changes aquagen Assembly and operating manual HOPPECKE Batterien GmbH Co KG P O Box 1140 D 59914 Brilon Germany Bont...

Отзывы: