Maintenance
Batteries_Rail_Power_Manual_en02.docx
38
Note
Note
The pole screws M8 with plastic head must be replaced by new ones because the screw
connection is secured with a micro-encapsulated adhesive.
For connections with M8 pole screws without plastic head, you can reuse the screws, but must
use new spring washers.
Torque: 20 Nm
Result: The rail.power blocks / cells are exchanged.
9.2.2.
Exchanging a cell connector
Target: A defect connector is exchanged.
Required tools:
•
Torque wrench with suitable widths for M8 screws
1. Loosen the terminal screws of the connector to be replaced.
2. Remove the defective connector.
3. Install the new connector and mount the pole screws.
Terminal screw M8 with plastic head;
Wrench opening 22 mm
Terminal screw M8
Spring washer
Pole shoe
Connector