35
5 Data strings
5.1 General information on the serial data output of the 6875 board
When setting ETX to the second change a transmission gap occurs, depending on the Baud
rate, of up to 970 msec. Please pay attention to this when programming timeout on the receiv-
ing side.
On all data strings the output of control character CR and LF can be exchanged with
mode-
byte.
The transmitted data string are compatible with the data strings of the following
hopf
clocks:
•
Board 6020/6021
standard with control character
•
Board 7200/7201
standard with control character
•
Board 7220/7221
standard with control character
•
Board 7240/7245
standard with control character
•
Board 6840/6841
standard with control character
•
System 4465 standard with control character
•
System 6870 standard with control character
5.2 Set-up of the standard (hopf6021) string
character no.: Meaning
Hex
1
STX (Start of Text)
$02
2
status (internal status of the clock)
$30-39, $41-46
3
day of the week (1=Monday ... 7=Sunday) $31-37
bit 3 in the day of the week is set to 1 with UTC
4 tens
hours
$30-32
5
unit hours
$30-39
6 tens
minutes
$30-35
7 unit
minutes
$30-39
8 tens
seconds
$30-36
9 unit
seconds
$30-39
10 tens
days
$30-33
11 unit
days
$30-39
12 tens
months
$30-31
13 unit
months
$30-39
14 tens
years
$30-39
15 unit
years
$30-39
16
LF (Line Feed)
$0A
17
CR (Carriage Return)
$0D
18
ETX (End of Text)
$03