4.3.14 Optical coupler
This section enables the configuration of 3 PhotoMOS signal relay outputs and 2 additional
pulses. The selection of the signal relay outputs to be configured ("
OK 1
", "
OK 2
" and "
OK 3
")
and the pulses ("
IMP 1
" und "
IMP 2
") is made by clicking on the upper part of the frame.
The current values for the selected output or pulse are requested and displayed. Depending on
the
"Modus"
which has been set additional methods of configuration will appear or fade. The
following modes are supported:
DCF77
(Mode 0)
In this setting the DCF77 pulse will be emitted at the appropriate output. This setting is used, for
example, for the synchronization of further DCF77radio-controlled clocks with DCF77 pulse in-
put such as
hopf
6850. If desired this signal can be inverted. The settings for the DCF77 pulse
are in the DCF77 menu and apply to all outputs emitting this.
Sync. Information
(Mode 1)
In this setting the internal clock radio-control status is emitted at the corresponding output. If the
PhotoMOs signal relay is switched through then the clock is in radio-controlled status. The laps-
ing of the signals indicates quartz mode. The signal output can not be inverted.
System Information
(Mode 2)
In this mode the corresponding output is switched through when the power supply is set. If there
is interference the signal lapses and hereby emits an alarm. The signal output cannot be in-
verted.