3.2  

Safety and Warning Instructions 

Please read these instructions thoroughly to facilitate safe operation of the equipment and to 
use all of its functions. 

 

 

 

Warning:

 Never work on live equipment on open devices! Danger to life! 

 

The 

hopf 

DIN Rail Module  is  a  built-in  device.  It  is  protected  for  installation  in  service 

access areas. Installation and commissioning may only be carried out by suitable specialist 
personnel. In doing so the respective country-specific regulations (e.g. VDE, DIN) are to be 
observed. 

In particular, before commissioning please ensure that: 

 

The  power  connection  has  been  installed  correctly  and  there  is  guaranteed 
protection against electric shock! 

 

The  device  can  be  switched  off  externally  to  the  power  supply,  in  accordance  with 
the provisions of EN 60950 (e.g. via the primary-side line protection)! 

 

The ground wire is connected! 

 

All power cables are correctly fused and sized! 

 

All output lines are sized in accordance with the max. output current of the device or 
are specially fused! 

 

Sufficient convection is guaranteed! 

 

The housing can become very hot dependent on the environment temperature and the load 
on the device! 

The  device  contains  components  with  life-threatening  voltage  and  a  high  amount  of  stored 
energy! 

 

Содержание 4465AC

Страница 1: ..._________ Additional Technical Manual for DIN Rail Modules 4465AC 4475AC 4800AC 6870AC 6875AC with AC Power Supply Type AC M05 D AC M10 D ENGLISH Version 01 03 17 06 2021 _____________________________...

Страница 2: ...4475AC 4800AC 6870AC 6875AC Additional Technical Manual V01 03 hopf Elektronik GmbH Nottebohmstr 41 D 58511 L denscheid Tel 49 0 2351 9386 86 Fax 49 0 2351 9386 93 Internet http www hopf com E Mail in...

Страница 3: ...hopf com E Mail info hopf com Downloading Technical Descriptions All current descriptions of our products are available free of charge via our homepage on the Internet Homepage http www hopf com E Ma...

Страница 4: ...ly be operated with the voltage supply indicated on the identification label The device should only be operated by qualified staff or employees who have received specific instruction If a device must...

Страница 5: ...f the Devices 7 2 Housing Installation 8 2 1 Mounting 8 2 2 Demounting 8 3 Power Supply 9 3 1 Power Supply Unit Specifications 9 3 2 Safety and Warning Instructions 10 3 3 Power Connection and Control...

Страница 6: ...4 4465AC 4475AC 4800AC 6870AC 6875AC Additional Technical Manual V01 03 hopf Elektronik GmbH Nottebohmstr 41 D 58511 L denscheid Tel 49 0 2351 9386 86 Fax 49 0 2351 9386 93 Internet http www hopf com...

Страница 7: ...supply for the different modules and replaces the technical specifications of the according manuals for those devices Changes in comparison to the standard with DC voltage input The voltage input via...

Страница 8: ...g Housing 4465AC with integrated AC power supply Housing TYPE 2 4475AC with integrated AC power supply Housing TYPE 2 4800AC with integrated AC power supply Housing TYPE 2 6870AC with integrated AC po...

Страница 9: ...AC typ 30A IO 100 200VAC Hold up time at nominal laod 20msec 100VAC 20msec 100VAC Start up time after connected mains voltage 1 sec 1 sec Transient overvoltage protection Overvoltage protection III EN...

Страница 10: ...specialist personnel In doing so the respective country specific regulations e g VDE DIN are to be observed In particular before commissioning please ensure that The power connection has been installe...

Страница 11: ...eration of the hopf DIN Rail Module power supply 3 3 1 Connection to Several Power Networks 3 3 2 Connection of the Power Cable The power cable is connected via a 3pole pluggable screw terminal The fo...

Страница 12: ...ower supply capable of switching the device off The primary side line protection for example is suitable for this purpose Further equipment protection is not required because the device is fused inter...

Страница 13: ...l 35mm DIN rail per DIN EN 50 022 Protection Type of the housing IP40 Protection Class I with PE connection MTBF 300 000h Type of housing Aluminium closed Dimensions W x H x D DIN Rail 100 x 105 x 130...

Страница 14: ...ung f r 35mm Hutschienenmontage DIN EN 50 022 35mm rail mounting DIN EN 50 022 Front Panel Parts Front Panel Parts W 105 00 4 13 2 50 0 10 2 50 0 10 26 80 1 06 50 00 1 97 105 00 4 13 C L All dimension...

Отзывы: