Technical Data 

4.1  

General 

The technical data in this document are only valid in connection with the technical manual of 
the according module. 

All specified data in this document replaces those of the appropriate technical manual of the 
module. 

Regarding all other articles the technical manual of the module is the relevant document. 

4.2  

Power Supply 

hopf 

DIN Rail Module 

General Data 

 

 Installation position 

On horizontal 35mm DIN rail per 
DIN EN 50 022 

 Protection Type of the housing 

IP40 

 Protection Class 

I, with PE connection 

 MTBF 

> 300,000h  

 Type of housing 

Aluminium, closed 

 Dimensions (W x H x D) + DIN Rail 

100 x 105 x 130mm (Type 2) 

 Weight 

approx. 1.05kg  

 

Climatic Data 

 

 Environmental temperature 

Operation 

   0° C ... +55° C  

 

Storage 

-20° C ... +75° C 

Humidity 

Up to 90% at +25° C, no condensation 

 

CE compliant to EMC Directive 89/336/EEC and Low Voltage Directive 73/23/EEC 

 Safety  -  Low Voltage Directive 

DIN EN 60950-1:2001 
+ A11 + Corrigendum 

 EN 61000-6-4: 

 

 EMC (Electro-Magnetic Compatibility) 
 Stability 

EN 610000-4-2 /-3/-4/-5/-6/-11 

 EN 61000-6-2: 

EN 61000 -3 -2 /-3  

 Interference Voltage  

EN 55022 

EN 55022 Class B 

 Interference Voltage  

EN 55022 

EN 55022 Class B 

 

4.3  

Power Supply 

Internal Power Supply

 

(with wide input range)

 

hopf 

type:  

AC-M05-D 

/

 AC-M10-D

 

Power consumption 

AC-M05-D

 

max. 6 VA 

Power consumption

 AC-M10-D

 

max. 15 VA 

Содержание 4465AC

Страница 1: ..._________ Additional Technical Manual for DIN Rail Modules 4465AC 4475AC 4800AC 6870AC 6875AC with AC Power Supply Type AC M05 D AC M10 D ENGLISH Version 01 03 17 06 2021 _____________________________...

Страница 2: ...4475AC 4800AC 6870AC 6875AC Additional Technical Manual V01 03 hopf Elektronik GmbH Nottebohmstr 41 D 58511 L denscheid Tel 49 0 2351 9386 86 Fax 49 0 2351 9386 93 Internet http www hopf com E Mail in...

Страница 3: ...hopf com E Mail info hopf com Downloading Technical Descriptions All current descriptions of our products are available free of charge via our homepage on the Internet Homepage http www hopf com E Ma...

Страница 4: ...ly be operated with the voltage supply indicated on the identification label The device should only be operated by qualified staff or employees who have received specific instruction If a device must...

Страница 5: ...f the Devices 7 2 Housing Installation 8 2 1 Mounting 8 2 2 Demounting 8 3 Power Supply 9 3 1 Power Supply Unit Specifications 9 3 2 Safety and Warning Instructions 10 3 3 Power Connection and Control...

Страница 6: ...4 4465AC 4475AC 4800AC 6870AC 6875AC Additional Technical Manual V01 03 hopf Elektronik GmbH Nottebohmstr 41 D 58511 L denscheid Tel 49 0 2351 9386 86 Fax 49 0 2351 9386 93 Internet http www hopf com...

Страница 7: ...supply for the different modules and replaces the technical specifications of the according manuals for those devices Changes in comparison to the standard with DC voltage input The voltage input via...

Страница 8: ...g Housing 4465AC with integrated AC power supply Housing TYPE 2 4475AC with integrated AC power supply Housing TYPE 2 4800AC with integrated AC power supply Housing TYPE 2 6870AC with integrated AC po...

Страница 9: ...AC typ 30A IO 100 200VAC Hold up time at nominal laod 20msec 100VAC 20msec 100VAC Start up time after connected mains voltage 1 sec 1 sec Transient overvoltage protection Overvoltage protection III EN...

Страница 10: ...specialist personnel In doing so the respective country specific regulations e g VDE DIN are to be observed In particular before commissioning please ensure that The power connection has been installe...

Страница 11: ...eration of the hopf DIN Rail Module power supply 3 3 1 Connection to Several Power Networks 3 3 2 Connection of the Power Cable The power cable is connected via a 3pole pluggable screw terminal The fo...

Страница 12: ...ower supply capable of switching the device off The primary side line protection for example is suitable for this purpose Further equipment protection is not required because the device is fused inter...

Страница 13: ...l 35mm DIN rail per DIN EN 50 022 Protection Type of the housing IP40 Protection Class I with PE connection MTBF 300 000h Type of housing Aluminium closed Dimensions W x H x D DIN Rail 100 x 105 x 130...

Страница 14: ...ung f r 35mm Hutschienenmontage DIN EN 50 022 35mm rail mounting DIN EN 50 022 Front Panel Parts Front Panel Parts W 105 00 4 13 2 50 0 10 2 50 0 10 26 80 1 06 50 00 1 97 105 00 4 13 C L All dimension...

Отзывы: