Page 59
RF65
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
ADVANCED COMMUNICATIONS & SENSING
DATASHEET
RegOokPeak
(0x1B)
7-6
OokThreshType
rw
01
Selects type of threshold in the OOK data slicer:
00
→
fixed
10
→
average
01
→
peak
11
→
reserved
5-3
OokPeakTheshStep
rw
000
Size of each decrement of the RSSI threshold in the OOK
demodulator:
000
→
0.5 dB
001
→
1.0 dB
010
→
1.5 dB
011
→
2.0 dB
100
→
3.0 dB
101
→
4.0 dB
110
→
5.0 dB
111
→
6.0 dB
2-0
OokPeakThreshDec
rw
000
Period of decrement of the RSSI threshold in the OOK
demodulator:
000
→
once per chip
001
→
once every 2 chips
010
→
once every 4 chips
011
→
once every 8 chips
100
→
twice in each chip
101
→
4 times in each chip
110
→
8 times in each chip 111
→
16 times in each chip
RegOokAvg
(0x1C)
7-6
OokAverageThreshFilt
rw
10
Filter coefficients in average mode of the OOK
demodulator:
00
→
f
C
≈ chip rate / 32.π
01
→
f
C
≈ chip rate / 8.π
10
→
f
C
≈ chip rate / 4.π
11
→
f
C
≈ chip rate / 2.π
5-0
-
r
000000
unused
RegOokFix
(0x1D)
7-0
OokFixedThresh
rw
0110
(6dB)
Fixed threshold value (in dB) in the OOK demodulator.
Used when
OokThresType
= 00
RegAfcFei
(0x1E)
7
-
r
0
unused
6
FeiDone
r
0
0
→
FEI is on-going
1
→
FEI finished
5
FeiStart
w
0
Triggers a FEI measurement when set. Always reads 0.
4
AfcDone
r
1
0
→
AFC is on-going
1
→
AFC has finished
3
AfcAutoclearOn
rw
0
Only valid if
AfcAutoOn
is set
0
→
AFC register is not cleared before a new AFC phase
1
→
AFC register is cleared before a new AFC phase
2
AfcAutoOn
rw
0
0
→
AFC is performed each time
AfcStart
is set
1
→
AFC is performed each time Rx mode is entered
1
AfcClear
w
0
Clears the AfcValue if set in Rx mode. Always reads 0
0
AfcStart
w
0
Triggers an AFC when set. Always reads 0.
RegAfcMsb
(0x1F)
7-0
AfcValue(15:8)
r
0x00
MSB of the AfcValue, 2
‟s complement format
RegAfcLsb
(0x20)
7-0
AfcValue(7:0)
r
0x00
LSB of the AfcValue, 2
‟s complement format
Frequency correction =
AfcValue x Fstep
RegFeiMsb
(0x21)
7-0
FeiValue(15:8)
r
-
MSB of the measured frequency offset, 2
‟s complement
RegFeiLsb
(0x22)
7-0
FeiValue(7:0)
r
-
LSB of the measured frequency offset, 2
‟s complement
Frequency error =
FeiValue x Fstep
RegRssiConfig
(0x23)
7-2
-
r
000000
unused
1
RssiDone
r
1
0
→
RSSI is on-going
1
→
RSSI sampling is finished, result available
0
RssiStart
w
0
Trigger a RSSI measurement when set. Always reads 0.
RegRssiValue
(0x24)
7-0
RssiValue
r
0xFF
Absolute value of the RSSI in dBm, 0.5dB steps.
RSSI = -
RssiValue/2 [dBm]