background image

12

3-24

3-25

The agitator brush roll

When to replace

When agitator brushes are worn, the
agitator should be replaced. 

To check condition of brushes, 

discon-

nect cleaner from electrical outlet.

Move edge of a card across bottom
plate while turning agitator. To maintain
cleaning effectiveness, replace agitator
if brushes do not touch card.

What to buy

Your cleaner requires either a 13” or 15”
agitator. When purchasing a new agita-
tor, ask for one of the following:

13” - 

HOOVER part No. 48414110

15”

- HOOVER part No. 48414115.

How to replace

Disconnect cleaner from electrical
outlet.

Remove bottom plate, belt and agitator
following directions in “The belt” section
beginning with Fig. 3-18.

Discard old agitator.

Continue following the directions in “The
belt” section to reposition belt, new
agitator and bottom plate.

Installing groomers

Lift off both old edge groomers and slide
new edge groomers into position as
shown.

Reposition bottom plate and secure with
(4) Phillips head screws.

Thermal protector

An internal thermal protector has been
designed into your cleaner to protect it
from overheating.

When the thermal protector activates,
the cleaner will stop running.

If this

happens, proceed as follows:

1. 

Turn the cleaner OFF and discon-

nect it from the electrical outlet.

2. Check secondary and final filters for

dirt accumulation.

3. Refer to “Clearing blockages”

section. 

4. 

When cleaner is unplugged and

the motor cools for 30 minutes,

the

thermal protector automatically resets
and cleaning may continue.

If the thermal protector continues to
activate after following the above steps,
your cleaner may need servicing

(see“Service” section).

Lubrication

The motor is equipped with bearings
that contain sufficient lubrication for the
life of the motor. The addition of lubricant
could cause damage. 

Therefore, do not

add lubricant to motor bearings.

The agitator brush roll is equipped with
two ball bearings that should be lubri-
cated periodically by a Hoover Factory
Service Center or an Authorized Hoover
Warranty Service Dealer (Depot).

Edge groomer 
replacement

When to replace

The edge groomers, located on both
sides of the nozzle, should be replaced
when they are worn.

What to buy

When purchasing edge groomers, ask
for HOOVER 

part No. 39511004.

How to replace

Disconnect cleaner from electrical
outlet.

Remove bottom plate as described in
“The belt” section (Fig. 3-18).

Содержание U5361

Страница 1: ...HOOVER Thank you for your purchase Bagless Upright This product was designed for easy assembly see page 3 www hoover com ENGLISH pp 1 14 ESPA OL p g 15 22 FRAN AIS p 23 30 Owner s Manual...

Страница 2: ...als Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes Do not use to pick up flammable or combustible materials such as gasoline or fine wood sandings or use in...

Страница 3: ...our Consumer Response Center Please do not return this product to the store Carton contents Empty carton Find the parts shown before disposing of packing materials A Handle section B Cleaner body C H...

Страница 4: ...a Phillips screw driver A B B A C D B E D Place bottom of cup into cleaner Pivot cup and snap in place Position cord on back of cleaner as shown and press cord into clip 1 11 1 13 Place smaller unrid...

Страница 5: ...escription A 2 How to use Operate cleaner only at voltage specified on data plate on bottom of cleaner This cleaner is intended for household use Polarized plug To reduce the risk of electric shock th...

Страница 6: ...end of rug and move cleaner toward other end or edge Before reaching edge push down on handle This will lift up the nozzle front of cleaner as shown and will prevent rug from clinging to cleaner Cont...

Страница 7: ...ges in such places as dresser drawers uphol stered furniture stairs and baseboards F Crevice wand stores inside exten sion wand can be used in tight spaces corners and along edges in such places as dr...

Страница 8: ...en collecting in the left side of the dirt cup The main filter will collect fine particles that have passed through the pre filter assembly screen 2 16 2 15 3 1 3 2 3 3 H Attach wand and tools Attach...

Страница 9: ...mbly all the way to bottom of cup Pivot pre filter assembly and snap in place Replace dirt cup lid If lid will not close completely the pre filter assembly is not positioned correctly Lay filter on to...

Страница 10: ...ks up so well we strongly recommend you check for debris accumulation under the agitator shield each time you clean the filters Removing debris under the shield will help maintain your cleaner s excel...

Страница 11: ...ide N Replace bottom plate Reposition bottom plate and 4 Phillips head screws Tighten screws securely Belt replacement The belt on your Hoover cleaner causes the agitator to rotate and is important fo...

Страница 12: ...overheating When the thermal protector activates the cleaner will stop running If this happens proceed as follows 1 Turn the cleaner OFF and discon nect it from the electrical outlet 2 Check secondar...

Страница 13: ...there is suction continue with step 5 b If there is no suction check for blockage in hose and dirt tube as follows 1 DIsconnect hose from dirt duct D by reversing procedure for Attach hose Fig 1 8 an...

Страница 14: ...d Warranty Service Dealers Depots For an automated referral of authorized service outlets in the U S A phone 1 800 944 9200 OR visit The Hoover Company on line at www hoover com This warranty does not...