Return nozzle to original position:
lift off nozzle cover.

If belt is not broken, pull it off the

motor pulley (A).

Lift up end of agitator. Remove old
belt from agitator and replace with

new belt (B). Lettering on belt must be

visible.

q

Stretch belt back and attach to

motor pulley (A).

Hold opposite end of agitator in place.
Push belt end forward, rotating end plate
(C) until it slides into place. Turn agita-

tor, making sure it rotates freely.

q

Position nozzle cover on front lip of
nozzle base. Press cover into

place.

Turn nozzle over and replace screws.

When agitator brushes are worn, the agita-
tor should be replaced.

. To check condition of brushes,

move edge of card across agitator

opening while turning agitator. To maintain
cleaning effectiveness, replace agitator if
brushes do not touch edge of card.

How to replace

The agitator may be replaced with either a
single or double row of brushes.

Single row of brushes   Hoover part No.

49414-051.

Double row of brushes   Hoover part No.

 Remove nozzle cover, agitator and belt

as shown in “How to replace belt”.

2. Discard old agitator.

3. Place new agitator as shown in figures
35-37 of “How to replace belt.”

The headlight

(Available on some models)

How to replace

Disconnect cleaner from electrical
outlet.

The headlight, located in the top of the
power nozzle, operates when the clean-
er is turned on. When replacing the
bulb, use only Hoover part No. 
307, which is a fused bulb.

I

 Remove the nozzle cover as shown in

2. Push old bulb into socket and

“How to replace belt”.

 twist to remove. Push new bulb

into socket and twist into place.

3. Replace nozzle cover.

8

Содержание Futura S3559

Страница 1: ...dy away from openings rotating agitator and other moving parts Do not operate cleaner in bare feet or when wearing open toe shoes or sandals l Do not pick up anything that is burning or smoking such a...

Страница 2: ...ip snaps onto wands Suction regulator close for maxi mum suction open if power nozzle is difficult to push on some carpets or if lightweight rugs or draperies are being cleaned 10 Plastic latch ring l...

Страница 3: ...atch A will automatically fasten To disconnect hose first remove hose cord plug from receptacle while pulling out on latch Then depress buttons shown in Fig 3 by arrows on hose con nector and pull up...

Страница 4: ...o not change the plug in any way a After assembling cleaner plug cord into electrical outlet Turn cleaner on by depressing ON OFF pedal A To turn cleaner off depress pedal again qOn models without cor...

Страница 5: ...ool q1 Crevice tool may be used in tight spaces corners and along edges in such places as dresser draw ers upholstered furniture stairs and baseboards 2 Furniture nozzle may be used for upholstered fu...

Страница 6: ...clip E on bottom of I cleaner The nozzle must be nosi hUUl l LU wp q C lean stairs by placing cleaner on end as shown Clean stairs from c l tioned down as shown Lift up on wand to remove storage clip...

Страница 7: ...r nozzle from wands and attach wands to hose Check for suction and remove any blockages q4 Before attaching power nozzle to wands check nozzle connector A While holding nozzle push nozzle con nector d...

Страница 8: ...gitator To maintain cleaning effectiveness replace agitator if brushes do not touch edge of card How to replace The agitator may be replaced with either a single or double row of brushes Single row of...

Страница 9: ...power cord not firmly plugged in l Plug firmly into receptacle on cleaner base l Broken or worn belt l Rep ace belt l Nozzle sealed to carpet l Open suction regulator Possible cause Possible solution...

Отзывы: