Set the therapy 
current! 
Place your hands, feet or 
armpit sponges        

          

2

mA

 

 

Therapy time is 
running! 

Remaining time 9 min. 

       

          

2

mA

 

If  you  feel  a  tingling  sensation  or  burning,  the  current 
intensity  is  too  high  and  must  be  scaled  down. 
 
If you do not feel a tingling sensation or light cauterisation, 
the  current  intensity  have  to  be  increased  until  a  tingling 
sensation  or  light  cauterisation occurs and then have to be 
decreased.

 

Regulate the current by turning the knob right or left until you feel 
a soft tingling sensation at the armpits. 

Repeat  this  process  until  the  tingling  sensation/burning  ends  or 
until you feel it and then turn the knob a little back to the left. 

When  treating  (15  minutes)  the  armpits,  the  sponge  electrodes 
have  to  be  kept  still  and  with  constant  pressure  under  the 
armpits.  Otherwise  there  will  occur  fluctuations  of  current  at  the 
display  of  the  unit  or  the  unit  can  display  a  malfunction 
information.

 

Take your hands, 

feet or 

armpit sponges out

 

Please 

switch off 

the machine!

 

If there is a break in treatment, the unit retains the remaining 
treatment time. 

At  the  end  of  the  treatment  remove  the  sponge electrodes from 
the armpits. 

Turn the knob to the switch setting (

) and switch off the unit by 

pushing down the knob. 

 

Always  check  the  position  of  the  turning  knob.  (Position 

)  immediately  after 

switching on the unit and the self-test completes. 

 

3. 

I

MPORTANT 

T

IPS AND 

I

NFORMATION

 

  To simplify therapy the current intensity in mA for your treatment (pleasant tingling sensation – 

aside from the treatment of the armpits) is displayed and can be set again consistently. 

  The maximum current and voltage are limited by safety limits prescribed for electrical medical 

equipment. Nevertheless, do not remove your hand and/or feet from  treatment tubs during the 
session  (keep  the  current  circuit  closed).  Take  care,  that  the  unit  is  not  switched  off  during  
treatment. 

  The inhibition of sweating is much more pronounced at the positive pole than at the negative 

pole.  In  order  to  optimize  the  therapeutic  effect,  you  should therefore switch polarities before 
every 5

th

 treatment session. To do this, you have only to swap the electrode leads. 

  Please  take  care,  that  the water you are using is normal tap water and has not been treated 

with  a  water  softener  before.  That  reduces  the  conductibility  of  water  and  treatment  can  be 
make only conditional or none. 

Содержание 110001

Страница 1: ...1 OPERATING INSTRUCTIONS idromed 5 PS Art No 110001 Art No 110003 Before putting the unit into operation and starting treatment read this operating manual carefully 110001 3 S0408 e ...

Страница 2: ...arge treatment tubs art no 995130 2 x distance grids for large treatment tubs art no 995131 Content 1 Important information on idromed 5 PS 3 1 1 Symbols and warning on the unit 4 1 2 Electromagnetical compatibility 4 2 Application of the idromed 5 PS 5 2 1 Fields of Application 5 2 2 Conditions of Application 5 2 3 Preparation of the Treatment 5 2 4 Treatment 6 2 4 1 Treatment of hyperhidrosis on...

Страница 3: ...d during treatment All jewellery on hands and feet must be removed before starting treatment Any damage to skin minor injuries scratches etc on the palms of the hands soles of the feet cuticles or at the armpits must be coated with vaseline or a fatty cream before treatment as current permeability will be higher than normal on those spots Please do only cover these spots Current intensity is set a...

Страница 4: ...cology Unit contains electronic parts and may not be disposed in the household rubbish 1 2 ELECTROMAGNETICAL COMPATIBILITY idromed 5 PS uses high frequency energy exclusively for its internal function Therefore its HF emission is very low and it is unlikely that surrounding electronic devices are disturbed HF emissions acc to CISPR 11 group 1 idromed 5 PS is determined for the use in all facilitie...

Страница 5: ...e manufacturer b For treatment you should separate the two parts of the case To do this open the case completely put it on a plain surface and separate the 2 parts carefully in opposite directions see arrows on the hinges on the case c Fill the 2 treatment tubs with tap water to a depth of approx 3 4 cm finger and toe joints should be just covered Please see also the warnings on page 10 point 4 3 ...

Страница 6: ...reatment of the feet or of hands and feet 25 mA For the treatment of the armpits 5 mA If the current intensity selected is too high you may experience an unpleasant tingling sensation in the extremities treated during the session If this occurs a lower current intensity has to be selected otherwise there is a danger of burns 2 4 1 TREATMENT OF HYPERHIDROSIS ON THE HANDS AND OR FEET Self test Maxim...

Страница 7: ...would break the circuit by taking one hand out of the tubs While adjusting the current hands or feet may be taken out of the treatment tubs and while the unit is still running without any danger Please dry your hands before regulating the current at the unit Regulate the current by turning the knob right or left and close the circuit again by putting again your hands in the treatment tubs Repeat t...

Страница 8: ...ect the electrodes with the positive and the negative pole of the unit Self test Maximum armpits 5mA Values hands 15mA feet 25mA Switch on the unit while pushing down the turning knob Pay attention that the turning knob is on switch setting The unit carries out a self test This action takes some seconds Set the therapy current Place your hands feet or armpit sponges 2mA Adjust the required current...

Страница 9: ...ns the remaining treatment time At the end of the treatment remove the sponge electrodes from the armpits Turn the knob to the switch setting and switch off the unit by pushing down the knob Always check the position of the turning knob Position immediately after switching on the unit and the self test completes 3 IMPORTANT TIPS AND INFORMATION To simplify therapy the current intensity in mA for y...

Страница 10: ...please contact Customer Services 4 3 Current intensity is adequate Check the connections of the plug and electrodes and the function of the unit Please check if the water you are using has been treated with a water softener By using softened water the conductivity is reduced In this case please use untreated tap water or use non carbonated still mineral or table water For the treatment of the armp...

Страница 11: ...lly the general Terms of Sales and Delivery of the company Dr K Hönle Medizintechnik GmbH shall apply These shall be submitted to the operator upon the signing of the contract at the very latest The warranty for the idromed 5 PS is 24 months Warranty and liability claims are excluded in case of personal injury or damage of property if these are attributable to one or more of the following causes T...

Страница 12: ...l be alight Once the unit has been switched off the lamp will be out Protection class II all insulated MDD classification IIa Protection against intrusion of liquids IPX1 CE Mark Output wave form Manufacturer A L T Lichttherapietechnik GmbH Thura Mark 10 D 06780 Zörbig Exclusive sales Dr K Hönle Medizintechnik GmbH Viktor Frankl Str 20 D 86916 Kaufering Tel 0049 8191 30555 0 Fax 0049 8191 30555 50...

Отзывы: