3.2
Configuring the Unit for the first time
The XYR301-E has a built-in web server, containing web pages for analyzing and modifying the module’s
configuration. The configuration can be accessed using Microsoft® Internet Explorer version 7 or greater. This
program is shipped with Microsoft Windows or may be obtained freely via the Microsoft® website. If using other
browsers they must be fully compliant with IE7 SSL security.
Note: Microsoft Internet Explorer Version 6 will not load web pages due to a compatibility issue between
IE6 and SSL-security web sites.
Default Configuration
The default factory configuration of the XYR301-E is
Client/Bridge/
IP address192.168.0.1XX, where XX is the last two digits of the serial number (the default IP address is
shown on the printed label on the back of the module)
netmask 255.255.255.0
Username is “
user
” and the default password is “
user
”
The XYR301-E will temporarily load some factory-default settings if powered up with the Factory Default switch (on
the end-plate of the module) in SETUP position.
When in SETUP mode, wireless operation is disabled.
The
previous configuration remains stored in non-volatile memory and will only change if a configuration parameter is
modified and the change saved.
Do not forget to set the switch back to the RUN position and cycle power at the conclusion of
configuration for resumption of normal operation.
Accessing Configuration for the first time
Because the Default IP address is in the range 192.168.0.XXX it may
not connect to you network or PC so there are two methods for
accessing the configuration for the first time.
Method 1 - Change your computer settings so that the configuring PC is
on the same network as the XYR301-E with factory default settings.
This is the preferred method
and is much less complicated than the
second method. You will need a “straight-through” Ethernet cable
between the PC Ethernet port and the XYR301-E. The factory default
Ethernet address for the XYR301-E is 192.168.0.1XX where XX are
the last two digits of the serial number (check the label on the back of
the module).
Method 2 - Requires temporarily changing the IP address in the
XYR301-E via an RS232 connection such that it is accessible on your
network without having to change your PC network settings. When
connected you can change the modem network settings to match that of
your network.