background image

33-00235 6

Initial Setup

Upon initial power up, or after being reset to factory defaults, the initial thermostat options 
(language, location, and system type) must be set to define the heating/cooling system. 
Other options can be customised later.
Follow prompts on the screen to select appropriate options.

1. Select the language of your choice, then 

touch 

Next

.

2. Select Home or Business installation, 

then touch 

Next

.

Touch 

Next

, or name the thermostat 

location - touch 

THERMOSTAT

 and follow 

the instructions.

3. Select what the thermostat will control 

and touch 

Next

.

Note

:

 Touch the orange Help button on the 

screen for more information.

4. Select the system type and touch 

Next

(The system type determines other 
selections for completing the initial setup.) 

5. Touch 

Next

 after making selections on 

each screen.

6. Touch 

Done

 on the last screen. The 

thermostat displays an option to connect 
to the Wi-Fi network.

Next

Next

Next

Next

Next

Содержание Wi-Fi Thermostat 9000

Страница 1: ...ol MENU Touch to display options Start here to set a program schedule CURRENT SCHEDULE Change temperature setting and select temporary or permanent hold INDOOR CONDITIONS Shows indoor temperature and humidity CURRENT DATE AND TIME CURRENT STATUS Shows system mode heat cool OUTDOOR CONDITIONS Shows outdoor temperature and humidity post registration ...

Страница 2: ...shock or equipment damage Disconnect power supply before beginning installation MERCURY NOTICE If this product is replacing a control that contains mercury in a sealed tube do not place the old control in the trash Drill 3 16 holes for drywall Drill 7 32 holes for plaster Wall anchors Wallplate Wire hole Mounting screws Wallplate Back of Thermostat ...

Страница 3: ...or heat pumps Y 1st stage compressor contactor G Fan relay W2 Aux E 2nd stage heat relay Or heat pump auxiliary Emergency heat relay Y2 2nd stage compressor contactor L Heat pump system monitor Jumper Loop a plug with a wire loop used to connect the R to the RC terminals Leave jumper loop in place in single transformer systems Remove unplug jumper loop in the two transformer systems Terminal Desig...

Страница 4: ...sformer systems 3 Common connection must come from cooling transformer Wiring Instructions 1 This thermostat requires a 24VAC common wire to power up The K terminal is available for Wiresaver module THP9045A1023 2 Straighten the wire Using a pen s tip hold down the terminal and gently slide the wire into the terminal hole Note Terminal hole will only accept one wire Jumper Loop Cool only System Rc...

Страница 5: ... the wire into the terminal hole Note Terminal hole will only accept one wire 1H 1C Heat Pump System Rc Power 1 R R Rc joined by jumper loop Y Compressor contactor C 24VAC common O B Changeover valve 7 G Fan relay 2H 1C Heat Pump System Rc Power 1 R R Rc joined by jumper loop Y Compressor contactor C 24VAC common O B Changeover valve 2 G Fan relay Aux E Auxiliary Emergency heat relay L Heat pump s...

Страница 6: ...elect Home or Business installation then touch Next Touch Next or name the thermostat location touch THERMOSTAT and follow the instructions 3 Select what the thermostat will control and touch Next Note Touch the orange Help button on the screen for more information 4 Select the system type and touch Next The system type determines other selections for completing the initial setup 5 Touch Next afte...

Страница 7: ...ncy of your heating system Select Standard Efficiency Forced Air default or High Efficiency Forced Air Your heating system type If you selected Hot Water or Steam on Your system type select the specific heating system here Number of cooling stages Select 1 Stage default or 2 Stages If you are unsure note which wires are connected Y wire only 1 stage or Y and Y2 Number of heating stages Select 1 St...

Страница 8: ...g MENU Wi Fi Setup Continue with Step 2 2 Select the network 2a Touch the name of the homeowner s network The thermostat displays a password page Note If the home network is not shown on the list touch Rescan 2b Using the keyboard enter the password for the home network 2c Touch Done The thermostat displays Connecting to your network Please wait then shows a Connection Successful screen 2d Touch N...

Страница 9: ...Periods Per Day Pre occupancy Purge Duration Select how long the fan will run before each occupied period Off 1 2 or 3 hours Type of Override Select Standard to maintain the programmed periods or Initiate Occupancy to use energy saving settings until a user presses Start Occupancy Override Duration Select how long to maintain temperature during an override 1 10 hours or No Limit Early Recovery for...

Страница 10: ... restart safely without causing damage to the compressor Heat pump issues cool air in heat mode or warm air in cool mode Check your setting for System Setup screen Type of changeover valve to make sure it is properly configured for your system see page 66 Heating or cooling system does not respond Touch SYSTEM to set system to Heat Make sure the temperature is set higher than the room temperature ...

Страница 11: ...F 10 to 37 C Operating Ambient Temperature 32 to 120 F 0 to 48 9 C Shipping Temperature 20 to 120 F 28 9 to 48 9 C Operating Relative Humidity 5 to 90 non condensing Physical Dimensions 4 1 2 W x 3 1 2 H x 7 8 D 115 mm W x 88 mm H x 22 mm D Electrical Ratings Terminal Voltage Max Current 50 60Hz Rating W O B 20 30 Vac 1 0 A W2 Aux E 20 30 Vac 1 0 A Y Cooling 20 30 Vac 1 0 A Y2 Cooling 20 30 Vac 1 ...

Страница 12: ...Help For assistance with this product please visit http customer honeywell com or call Honeywell Customer Care toll free at 1300 363 936 U S Registered Trademark Patents pending Apple iPhone iPad iPod touch and iTunes are trademarks of Apple Inc All other trademarks are the property of their respective owners 33 00236 01 10 16 2016 Honeywell International Inc For more information http customer hon...