Honeywell VS8421 Скачать руководство пользователя страница 1

® U.S. Registered Trademark
Copyright © 2000 Honeywell  • All Rights Reserved 

INSTALLATION INSTRUCTIONS

Place Bar Code Here

69- 1219- 1

VS8421

 Ventfree Millivolt Gas Valve

APPLICATION

The VS8421 Millivolt Gas Valve is compact and has a 
60,000 Btuh capacity (1 in. pressure drop for 
straight-through configuration). The design makes it ideal 
for fireplace and space heating applications that are 
ventfree (unvented). This valve is only for ventfree 
(unvented) applications.

SPECIFICATIONS

Main Gas Connection: 

Valve: 3/8 in. NPT thread.

Pilot Gas Connection, Flow and Adjustment:

Connection Size: 7/16-24 UNS.
Flow: 1700 Btuh at 4.0 in. wc pressure drop.
Pilot is not adjustable.

Thermocouple Connection:  

M8 x 1.

Pilot Threads: 

Metric and UNS.

Ambient Temperature Range:

0°F to 175°F (-18°C to 79°C).
Option for -40°F (-40°C) and 225°F (107°C).

Pressure Regulation (Standard Regulator):

Servo regulator with adjustable outlet pressure.
Natural Gas: 3.5 in. wc, typical.
LP: 11 in. wc, typical.

Regulator Adjustments (Standard Regulator):

Natural Gas: 3 in. to 5 in. field adjustable.
LP: 8 in. to 12 in. field adjustable.

Voltage: 

VS8421: 750 mV operator,  thermocouple in 

ODS pilot burner.

Approvals:

International Approval Services (IAS) Certificate: 

C2030022.

European Community (CE) Certificate: Applied for.

INSTALLATION

When Installing this Product...

1.

Read these instructions carefully. Failure to follow 
them could damage the product or cause a 
hazardous condition.

2.

Check the ratings given in the instructions and on 
the product to make sure the product is suitable for 
your application.

3.

Installer must be a trained, experienced service 
technician.

4.

After installation is complete, check out product 
operation as provided in these instructions.

WARNING

Oxygen Depletion Hazard.
Can cause injury or death due to 
asphyxiation.

Use only vented gas valve models on vented 
appliances. Use only unvented gas valve models 
on unvented appliances.

WARNING

Fire or Explosion Hazard.
Can cause property damage, severe injury 
or death.

Follow these instructions exactly:

1. Turn off gas supply at the appliance service 

valve before starting installation, and perform 
a Gas Leak Test after the installation is 
complete.

2. Always install the sediment trap in the gas 

supply line to prevent contamination of the 
gas valve.

3. Do not force the gas valve control knob. Use 

only your hand to turn the control knob. If the 
knob does not operate by hand, the valve 
should be replaced by a qualified service 
technician.

69-1219-1.fm  Page 1  Thursday, August 18, 2011  7:32 AM

This is a legacy product document  
supported by Resideo. It is no  
longer manufactured 

Содержание VS8421

Страница 1: ...icate C2030022 European Community CE Certificate Applied for INSTALLATION When Installing this Product 1 Read these instructions carefully Failure to follow them could damage the product or cause a hazardous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technicia...

Страница 2: ...lies Tubing installation must comply with approved standards and practices 1 Use new properly reamed pipe free from chips When tubing is used assure the ends are square deburred and clean All tubing bends must be smooth and without deformation 2 Run pipe or tubing to the valve If tubing is used obtain a tube to pipe coupling to connect the tubing to the valve 3 Install sediment trap in the supply ...

Страница 3: ...s valve M12670 HI LO REGULATOR WIRING TERMINALS INLET PRESSURE TAP OUTLET PRESSURE TAP GAS CONTROL KNOB OFF PILOT ON PRESSURE REGULATOR ADJUSTMENT UNDER CAP SCREW M12673 WIRING TERMINALS INLET PRESSURE TAP OUTLET PRESSURE TAP GAS CONTROL KNOB OFF PILOT ON PIEZO SPARKER APPLY WRENCH FROM BOTTOM OF GAS CONTROL TO SHADED AREA M12679 69 1219 1 fm Page 3 Thursday August 18 2011 7 32 AM ...

Страница 4: ...he pilot burner The piezo creates a spark when the plunger is depressed The connecting wires of the piezo include a terminal to connect to the electrode of the pilot burner The piezo is replaceable Refer to the installation instructions for the piezo envelope assembly part no 396079 form 69 1206 Fig 6 Millivolt system wiring diagram with ODS pilot burner Pilot Gas Lighting Procedure Lighting Stand...

Страница 5: ...rate using the meter clocking method or measure the pressure by attaching a plastic tube with a 1 4 in shell ID to the manometer and connecting the manometer to the outlet pressure tap on the gas valve See Fig 4 3 If necessary adjust the pressure regulator to match the appliance rating See Table 1 for factory set nominal outlet pressure and adjustment range a Remove the pressure regulator adjustme...

Страница 6: ...pliance being checked NOTE Other appliances must remain off with the pilots extinguished or the consumption must be deducted from the meter reading 2 Convert the flow rate to Btuh as described in the Gas Controls Handbook form 70 2602 3 Compare to the Btuh input rating on the appliance nameplate Checking Gas Input With Manometer NOTE Both the inlet and outlet pressure taps have a captive screw 1 B...

Страница 7: ...UTION Equipment Damage Can burn out heat anticipator in thermostat Do not apply a jumper across or short the valve coil terminals even temporarily If Main Burner Does Not Come On With Call For Heat 1 Confirm that the gas control knob is in the ON position 2 Adjust the thermostat several degrees above the room temperature 3 Use a dc voltmeter to measure the voltage across the THTP and TP terminals ...

Страница 8: ... is less than 12 mV replace the ODS pilot burner assembly The power unit will hold in down to 3 mV If the output of the thermocouple is less than 3 mV replace the ODS pilot burner assembly 4 Test D Operator Pull In have thermostat contacts open and pilot lit with Pilotstat knob turned to PILOT Close the thermostat contacts Operator will pull in with a minimum of 155 mV Operator makes audible sound...